For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Protein Precipatation vs. Ion Suppression of Medium Polar Drugs on strata Impact Square Well Plate
15712
Separation Mode: Reversed Phase
Reversed Phase
C18
HPLC
Antihypertensive Agents
Pharmaceutical
Therapeutic / Clinical

Applications

Protein Precipatation vs. Ion Suppression of Medium Polar Drugs on strata Impact Square Well Plate
Analytes
1Pindolol
2Metoprolol
Compound Name
Pindolol
CID
4828
Molecular Formula
C14H20N2O2
Molecular Weight
248
No. Chiral Centers:
1
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Details
LC Conditions (App ID: 15712)
Column:
Brand Name:
Part No:
Phase Name:
C18
Elution Type:
Gradient
Mobile Phase:
A: 0.1% Formic acid/Water
B: 0.08% Formic acid/Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
109010
255050
375050
Flow Rate:
0.5 mL/min
Temperature:
22°C
Detection:
Mass Spectrometer (MS) @ 249 amu (22°C)
Sample Note:
Protein Precipitation Protocol: Phase: Strata Impact Square Well Plate, 2 mL (CEO-7565) 1. Dispense 300 uL acetonitrile into each well using an automatic pipettor. 2. Place the protein precipitation plate onto a suitable 96-well vacuum manifold . Make sure that a 96-well collection plate is positioned inside the manifold to collect the filtrate. 3. Dispense 100 uL of Porcine plasma into each well ( acetonitrile:plasma = 3:1). Let it stand for 2 mins (no vortex /mixing required). 4. Apply 5-10" of mercury for 30-40 secs. 5. Collect the filtrate and blow down to dryness under slow stream of nitrogen @ 40 deg. C. 6. Reconstitute with 100 uL of mobile phase containing 10.0 ng of analye. Note: For ion suppression or enhancement estimation, a set of 4 blank (100 uL of water instead of plasma) was run in parallel. Observation: Filtrate looked very clean and clear Results: Analyte logP m/z % Variation Effect 1. Pindolol 1.75 249 15% Suppression 2. Metoprolol 1.88 268 13% Suppression