FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Catecholamines metabolites using Synergi Fusion-RP
15739
Separation Mode: Reversed Phase
Reversed Phase
Fusion-RP
HPLC
Clinical
Biochemical - NOT Polymeric (incl. oligomers)
Biochemical Compound / Nutrient

Applications

Catecholamines metabolites using Synergi Fusion-RP
Analytes
1Vanillylmandelic acid
23,4-Dihydroxyphenylacetic acid (DOPAC)
35-Hydroxyindoleacetic acid
4Homovanillic acid
Compound Name
Vanilmandelic Acid
CID
1245
Molecular Formula
C9H10O5
Molecular Weight
198
No. Chiral Centers:
1
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
3
Details
LC Conditions (App ID: 15739)
Column:
Brand Name:
Part No:
Phase Name:
Fusion-RP
Elution Type:
Gradient
Mobile Phase:
A: 20mM Ammonium formate, pH 3.5
B: Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
108020
2105050
Flow Rate:
1 mL/min
Temperature:
22°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 260 nm (22°C)
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Fusion-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-7557 - Holder Part No.: KJ0-4282