FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
EPA 1613 Polychlorinated Dibenzo-p-dioxins on ZB-5MS
15884
Separation Mode: Standard
Standard
EPA 1613
ZB-5MS
GC
Teratogens
Environmental
Pollutant / Contaminant
Environmental / Health

Applications

EPA 1613 Polychlorinated Dibenzo-p-dioxins on ZB-5MS
Analytes
11,3,6,8-TCDD
21,2,3,7/1,2,3,8-TCDD
31,2,3,9-TCDD
42,3,7,8-TCDD
51,2,8,9-TCDD
61,2,4,6,8/1,2,4,7,9-PnCDD
71,2,3,7,8-PnCDD
81,2,3,6,7-PnCDD
91,2,3,8,9-PnCDD
101,2,4,6,7,9/1,2,4,6,8,9-HxCDD
111,2,3,4,7,8-HxCDD
121,2,3,6,7,8-HxCDD
131,2,3,4,6,7-HxCDD
141,2,3,7,8,9-HxCDD
151,2,3,4,6,7,9-HpCDD
161,2,3,4,6,7,8-HpCDD
Compound Name
1,3,6,8-Tetrachlorodibenzodioxin
CID
36474
Molecular Formula
C12H4Cl4O2
Molecular Weight
321
No. Hydrogen Bond Acceptors
2
Details
Official Method: EPA 1613
GC Conditions (App ID: 15884)
Column:
Part No:
Phase Name:
ZB-5MS
Injection:
Splitless @ 250°C, 2.0 μL
Oven Program:
120°C for 1 min to 220°C at 20°C/min for 16 min to 235°C at 5°C/min for 7 min to 300°C at 5°C/min for 15 min
Carrier Gas:
Constant Flow Helium, 26.0 cm/sec
Detection:
High Res Mass Spec (HRMS) (290°C)
Sample Notes:
Notes: Flow 26cm/sec @ 200°C. Only selected chromatograms shown below. For the complete set of Single Ion Chromatograms, showing both Polychlorinated Dibenzo-p-dioxins and Polychlorinated Dibenzofurans, please contact your Phenomenex Technical Consultant. Mass Chromatograms are courtesy of V.N. Fishman, G.D. Martin, and L.L. Lamparski, The Dow Chemical Company, Midland, Michigan, USA This information is considered accurate and reliable as of the date appearing above and is presented in good faith. Because use conditions and applicable laws may differ from one location to another and may change with time, recipient is responsible for determining whether the information in this document is appropriate for recipient's use. Since Dow has no control over how this information may be ultimately used, all liability is expressly disclaimed and Dow assumes no obligation or liability therefore. No warranty, express or implied, is given nor is freedom from any patent owned by The Dow Chemical Company or others to be inferred.