Region

Applications

Mycotoxins on Kinetex 2.6µm C18 50 x 2.1mm ID by LCMS in ESI Positive Mode (1)

Sample Preparation Details

Part No:8B-S016-EBJ
Solid Phase Extraction (SPE) procedure:Note: The solvent volumes shown below are for a 100 mg bed mass. The solvent volumes will need to be adjusted for a smaller or larger bed mass.
Load:2 ml of Urine sample (spiked with analyte and IS at 100ng/mL) diluted with 100 mM phosphate buffer, pH 6.
Dry:2-3 mins at 10" of Hg
Final Prep and Analysis: Inject: 2 µL on HPLC / Mass Spectrometer (MS) @ amu (ambient)

Analytes:

Name Spiked
Conc.
Log P pKa % Rec %RSC (n=0)
1 Fumonisin B1 0.2 
2 HT-2 0.5 
3 T2-Toxin 0.5 
4 Fumonisin B2 0.2 
5 Ochratoxin 0.2 

Application Detail (App ID: 18878)

Part No:00B-4462-AN
Dimensions:50 x 2.1 mm ID
Elution Type:Gradient
Elution A:0.1% Formic acid
Elution B:0.1% Formic acid in Acetonitrile
Gradient Profile:
Step No. Time (min) Pct A Pct B
1 0 70 30
2 3 5 95
3 4 5 95
4 4.01 70 30
5 6 70 30

Flow Rate:400 µL/min
Col. Temp: 25 °C
Detection: Mass Spectrometer (MS) @ amu (22°C)
Detector Info: ESI conditions
Positive Ionization
NEB: 12.00
CUR: 11.00
IS: 4500.00
TEM: 450.00
CAD: 11.00
EP 10.00
Note:SecurityGuard™ ULTRA Guard Cartridge System extends column lifetime.
- SecurityGuard ULTRA Cartridges, UHPLC C18 for 2.1mm ID Columns, 3/Pk Part No.: AJ0-8782
- Holder Part No.: AJ0-9000

Analyte Details

Analyte Detail not available

1
Fumonisin B1
search

2
HT-2
search

3
T2-Toxin
search

4
Fumonisin B2
search

5
Ochratoxin
search