FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Narcotics 8-mix at Neutral pH on Kinetex 2.6 µm C18, 50 x 2.1mm
19184
Separation Mode: Reversed Phase
Reversed Phase
C18
HPLC
Anesthetics, Local
Forensics/Toxicology
Toxicology / Drug Screening / TDM
Therapeutic / Clinical

Applications

Narcotics 8-mix at Neutral pH on Kinetex 2.6 µm C18, 50 x 2.1mm
Analytes
1Normorphine
2Morphine
3Hydromorphone
4Norcodeine
5Codeine
6Hydrocodone
7Cocaine
8Norcocaine
Compound Name
Normorphine
CID
5359401
Molecular Formula
C16H17NO3
Molecular Weight
271
No. Chiral Centers:
1
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
3
Details
LC Conditions (App ID: 19184)
Column:
Brand Name:
Kinetex
Part No:
Phase Name:
C18
Elution Type:
Gradient
Mobile Phase:
A: 10mM NH4OAc pH5.5
B: ACN
Gradient Profile:
Step No.Time(min)%A%B
10955
20.25955
326040
42.01955
53955
Flow Rate:
0.8 mL/min
Temperature:
0°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 254 nm (22°C)
Detector Info:
550 bar back pressure