For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Ibuprofen by HPLC for Kinetex 2.6um XB-C18, 75x4.6mm
19660
Separation Mode: Reversed Phase
Reversed Phase
XB-C18
HPLC
Anti-Inflammatory Agents, Non-Steroidal
Pharmaceutical/Biopharmaceutical

Applications

Ibuprofen by HPLC for Kinetex 2.6um XB-C18, 75x4.6mm
Analytes
1Ibuprofen
2Valerophenone
3Ibuprofen related compound C
Compound Name
Ibuprofen
CID
3672
Molecular Formula
C13H18O2
Molecular Weight
206
No. Chiral Centers:
1
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Details
LC Conditions (App ID: 19660)
Column:
Brand Name:
Kinetex
Part No:
Phase Name:
XB-C18
Elution Type:
Isocratic
Mobile Phase:
A: 600:400 Acetonitrile: Water with 4g of chloroacetic acid adjusted to pH 3.0 with ammonium hydroxide
Gradient Profile:
Step No.Time(min)%A
110100
Flow Rate:
2 mL/min
Temperature:
0°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 254 nm (22°C)

Order Items Used in This Application

Similar Applications
search
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA
Reversed Phase
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, EA
Reversed Phase
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase