For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Antihistamines
2563
Separation Mode: Reversed Phase
Reversed Phase
C18(2)
HPLC
Antipruritics
Pharmaceutical
Therapeutic / Clinical

Applications

Antihistamines
Analytes
1Benzhydrol
2Benzophenone
3Diphenhydramine
Compound Name
Benzhydrol
CID
7037
Molecular Formula
C13H12O
Molecular Weight
184
No. Hydrogen Bond Acceptors
1
No. Hydrogen Bond Donors
1
Details
LC Conditions (App ID: 2563)
Column:
Brand Name:
Part No:
Phase Name:
C18(2)
Elution Type:
Isocratic
Mobile Phase:
A: Methanol
B: K2HPO4 pH 7.0
Gradient Profile:
Step No.Time(min)%A%B
106535
Flow Rate:
1.5 mL/min
Temperature:
22°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 220 nm (22°C)
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Similar Applications
search
No Data