;
Region

Zebron GC Information


Get More Than Just A Column

VIDEO: Our Innovation

Customers Come First

VIDEO: Our Quality

 

 

What Customers Are Saying

"The Zebron ZB-5 column has proven to be a winner. It produces high resolution chromatography in a very reliable manner. Guaranteed quality at an affordable price, you can't go wrong."

Carl Adix, BASF Corporation

"I analyze phenolics by GC/MS. After each run with [Agilent] J&W's DB-5 I had to clean the injector and replace the gold seal and inlet line and trim 4 to 5 feet of column. After most runs with Zebron, I could get away with just changing the inlet and not having to clean or trim the column. The separation was the same, but the Zebron lasted about 4 to 5 times longer, which for means means saving at least $5,000 a year."

Sam Sabella, BASF

"I was very glad to receive all six ZB-WAX columns overnight. It was nice to know that even if we order columns at 5:00 pm (Eastern Time), you can deliver them overnight! How simple to order!"

Analytical Chemist, Industrial Chemical Company

"The chromatography quality and performance are excellent. Column bleed is minimal at 320 °C. Peak quality remains good for 5 to 6 months averaging 40 injections in a 24 hour period, 6 to 7 days per week."

Kevin Walkup, Specialized Assays, Inc.

 

ZB-MultiResidue-1 Phase Detail


ZB-MultiResidue-1 Phase Information


Guaranteed Performance for Pesticides and Insecticides

  • Specially engineered column set specifically designed for pesticide screening and confirmation by GC/ECD, GC/NPD, and GC/MS
  • Resolve common pesticide isomers with optimized selectivity for food and environmental samples
  • Improved inertness for decreased breakdown of sensitive pesticides such as DDT
  • Exceed EPA Method 8081 specifications for dual column confirmation when used with ZB-MultiResidue-2

   Need an alternate selectivity for dual-column GC/ECD confirmation? See ZB-MultiResidue-2.
   Running chlorinated herbicides or haloacetic acids? Pair ZB-XLB and ZB-35.

Recommended Use

Aroclors/PCBs, Haloacetic Acids, Herbicides, Insecticides, Multi-Pesticide Screening, Nitrogen Containing Pesticides, Organochlorine Pesticides, Organophosphorous Pesticides

 

Featured Applications

Fast Organochlorine Pesticides on Zebron ZB-MultiResidue-1

Fast Organochlorine Pesticides on Zebron ZB-MultiResidue-1

View All Applications on ZB-MultiResidue-1 »

Document Type:
Document Type Title
Technical Notes A Simple and Rapid Extraction Method for Chlorinated Pesticides from poultry fat using SPE and GCECD (TN-0090) Add to My Documents
Technical Notes Drugs of Abuse Panel from Urine by GC/MS and LC/MS (TN-0041) Add to My Documents
Brochures Custom Method Development and Optimization Services for Clinical Research Add to My Documents
Other Environmental Testing Guide Add to My Documents
Other Essential Guide for Biofuel Analysis Add to My Documents
Technical Notes Endothalls in Water by EPA Method 548.1 using SPE and GC/MS (TN-0067) Add to My Documents
Brochures Food Testing Sample Preparation Guide Add to My Documents
Brochures GC Accessories: Product Overview Guide Add to My Documents
Other Zebron GC Column Selection Poster Add to My Documents
Other GC Troubleshooting Guide Add to My Documents
Technical Notes Improved Analysis of EPA Method 625 Using Large- Particle, Large-Pore Solid Phase Extraction (SPE) Add to My Documents
Technical Notes Improved Analysis of EPA Method 8270D (TN-2049) Add to My Documents
Technical Notes Improved Analysis of Flavor Compounds In Scotch Whiskey Using An Aqueous-Stable Polyethylene Glycol Stationary Phase Add to My Documents
Brochures Pesticide Analysis by GC/LC/Sample Prep Add to My Documents
Other Pharmaceutical Analysis Guide- Formulations Add to My Documents
Technical Notes BTEX by GC (TN-2001) Add to My Documents
Technical Notes Organic Compounds Analysis in Drinking Water (EPA 525.2) by GC (TN-2004) Add to My Documents
Technical Notes VOA Analysis (EPA 8260B) by GC (TN-2005) Add to My Documents
Technical Notes PONA Analysis on Gasoline Fractions by GC (TN-2006) Add to My Documents
Technical Notes Enhanced Results of Diesel Range Organics (DROs) (TN-2015) Add to My Documents
Technical Notes Considerations for Using Narrow Bore (0.10 mm) GC Columns (TN-2015) Add to My Documents
Technical Notes A Simple Guide to Improving GC Column Lifetime (TN-2017) Add to My Documents
Technical Notes Considerations When Optimizing Your GC Method: Phase Ratio (TN-2018) Add to My Documents
Technical Notes The Importance of System Conditioning After Installing a New Gas Chromatography Column (TN-2019) Add to My Documents
Technical Notes Troubleshooting Problems When Lighting a GC/FID (TN-2020) Add to My Documents
Technical Notes Multi-Residue Pesticide Screening by GC/MS (TN-2021) Add to My Documents
Technical Notes Diesel Fractionation by GC Following the Revised Massachussets EPH Guidelines (TN-2022) Add to My Documents
Technical Notes Aqueuos Stability for Distilled Spirits Testing by GC (TN-2025) Add to My Documents
Technical Notes Chlorinated Pesticides by GC (EPA 8081) (TN-2026) Add to My Documents
Technical Notes Polyaromatic Hydrocarbons (PAHs) by GC (TN-2027) Add to My Documents
Technical Notes Understanding the Revisions to USP Monograph <467>: Residual Solvents (TN-2028) Add to My Documents
Technical Notes Accurate and Painless GC Column Installation (TN-2029) Add to My Documents
Technical Notes Glycerin in Biodiesel Using a High Temperature Fused Silica GC Column (TN-2030) Add to My Documents
Technical Notes Split Injections in Gas Chromatography: How to Reduce Inlet Discrimination By Using a Liner with Glass Wool (TN-2031) Add to My Documents
Technical Notes Revised USP Chapter 467 and its Application to Excipient Qualification and Testing (TN-2032) Add to My Documents
Technical Notes Bioethanol Analysis by GC Following ASTM Method D 5501 (TN-2033) Add to My Documents
Technical Notes Blood Alcohols by GC (TN-2036) Add to My Documents
Technical Notes 2 Ways to Attain Sharper Peak Shape and Higher Sensitivity in Gas Chromatography (TN-2038) Add to My Documents
Technical Notes Chlorinated Pesticides by GC/ECD (TN-2039) Add to My Documents
Technical Notes Opiates from Urine by GC/MS and LC/MS/MS (TN-2040) Add to My Documents
Technical Notes Blood Alcohol Internal Standard Selection for Post Mortem Samples by GC (TN-2041) Add to My Documents
Technical Notes Easy and Painless GC Column Installation (TN-2042) Add to My Documents
Technical Notes Simulated Distillation (ASTM D6352 and D71679) by GC (TN-2043) Add to My Documents
Technical Notes Blood Alcohol Analysis by Resolution of Propanol from Ethanol by GC (TN-2044) Add to My Documents
Technical Notes Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC (TN-2045) Add to My Documents
Technical Notes Gulf Oil Dispersants (COREXIT 9527 and 9500) by GC/MS and LC/MS/MS (TN-2046) Add to My Documents
Technical Notes EPA Method 8270D by GC (TN-2050) Add to My Documents
Technical Notes Diesel Range Organics Analysis by High Temperature GC (TN-2051) Add to My Documents
Brochures Zebron ZB-5MSplus GC Columns Add to My Documents
Brochures Zebron ZB-1XT SimDist GC Columns Add to My Documents
Brochures Zebron ZB-CLPesticides GC Columns Add to My Documents
Brochures Zebron ZB-SemiVolatiles GC Columns Add to My Documents
Brochures Zebron ZB-WAXplus GC Columns Add to My Documents
Brochures GC Accessories: Cool-Lock Installation Nut Add to My Documents
Technical Notes Drugs of Abuse Analysis by GC/MS using a Zebron ZB-5MSplus Add to My Documents
Brochures GC Accessories: Easy Seals Inlet Base Seals Add to My Documents
Technical Notes Environmental Contaminants from Oil Spills (TN-2045) Add to My Documents
Technical Notes Ethanolamine Analysis by GC/MS using a Zebron ZB-5MSplus Add to My Documents
Technical Notes Extraction and GC/MS Analysis of Cannabinoids from Brownies using roQ QuEChERS Extraction Salts and a Zebron ZB-5MSplus GC Column Add to My Documents
Technical Notes Extraction and GC/MS Analysis of Melamine From Dog Food using a Zebron ZB-5MSplus GC column Add to My Documents
Technical Notes Haloacetic Acids from Water by GC/ECD (TN-0039) Add to My Documents
Technical Notes Polycyclic Aromatic Hydrocarbons (PAHs) by GC/MS and LC/MS (TN-0042) Add to My Documents
Technical Notes Improved Resolution of Triazine Herbicides (TN-2052) Add to My Documents
Technical Notes Oil Dispersants (COREXIT 9527 and 9500) by GC/MS and LC/MS/MS (TN-2046) Add to My Documents
Technical Notes Melamine and Cyanuric Acid by LC/MS/MS (TN-0021) Add to My Documents
Technical Notes Converting from Packed to Capillary GC Columns (TN-2016) Add to My Documents
Technical Notes Polychlorinated Biphenyls (PCBs) Designated as Toxic by the World Health Organization (WHO) by GC/MS (TN-2023) Add to My Documents
Technical Notes The Effect of Temperature on Compound Elution Order in GC (TN-2034) Add to My Documents
Technical Notes Single-Run Analysis of PBDEs Including BDE-209 on Zebron ZB-SemiVolatiles (TN-2054) Add to My Documents
Technical Notes EPA Method 508.1 with Automated Extraction by GC/ECD (TN-0050) Add to My Documents
Brochures Zebron ZB-MultiResidue GC Columns Add to My Documents
Brochures Zebron PLUS GC Inlet Liners Add to My Documents
Brochures GC Inlet Liners Add to My Documents
Brochures GC Method Development GUide Add to My Documents
Brochures Zebron Inferno GC Columns Add to My Documents
Brochures Zebron ZB-Bioethanol GC Columns Add to My Documents
Phase: Length: Internal Diameter: Film Thickness: Composition: Min Temp (C): Max Temp – TPGC (C):
Loading...

Part Number:

Description:

Composition:

Recommended Use:

Composition:Composition

Temp.Limits(C):

Polarity:

MS Certified:

USP Designation:

Recommended Use:

     Search Results


    Part
    Number
    Brand Phase Length (m) Internal
    Diameter (mm)
    Film
    Thickness (µm)
    Price