Guardian™: Integrated Guard Columns

Built-In Column Protection
  • 5 or 10 meter guard built directly into the analytical column in one continuous length of tubing
  • Provides the same inert column protection
  • Eliminates the possibility of leaks

Extend Column Lifetime Up to 20 %!
Impurities are trapped within the first 4-6 inches of the integrated guard section, allowing easy removal of contaminants by column trimming. The guard section of the column does not contain stationary phase, so separation is not affected!

Don't see the Zebron Guardian phase you need below? Contact your GC Specialist »


Technical Documents:

Document Type:
Document Type Title
Technical Notes Analysis of 20 Terpenes in Cannabis by GC-FID using Zebron ZB-624PLUS GC Column

Summary

This Application note documents the analysis for identifying, quantifying the terpenes and content in cannabis products for both quality and branding purposes Using ZB-624 PLUS GC Column

Technical Notes Analysis of 33 Primary and Secondary Terpenes Found in Cannabis by GC-FID

Summary

There are over 100 terpenes found in cannabis. Developed is a GC-FID method with excellent resolution and peak-shape for 33 primary and secondary terpenes found in cannabis. The selectivity and high temperature limits of the Zebron™ ZB-5PLUS allows for great resolution of key terpenes and high bake out for the removal of low volatile matrix contaminants that may be present.

Technical Notes Determination of Residual Solvents and Terpenes in Cannabis by GC-FID using Zebron™ ZB-624plus™ GC Column

Summary

Determination of Residual Solvents and Terpenes in Cannabis by GC-FID using Zebron™ ZB-624plus™ GC Column

Brochures GC Environmental Selection Guide

Summary

Easily select the appropriate GC column for your Environmental testing needs. The guide offers an easy to use selection chart along with some key GC applications used in Environmental testing.

Supporting Docs GC Resources Flyer

Summary

GC Resources

Technical Notes Purgeable Volatile Organic Compounds by GC-MS using Zebron™ ZB-624PLUS™ GC Columns

Summary

Purgeable Volatile Organic Compounds by GC-MS using Zebron™ ZB-624PLUS™ GC Columns

Technical Notes Residual Solvents per USP 467 using Zebron™ ZB-624PLUS™ and ZB-WAXPLUS™ GC Columns

Summary

Residual Solvents per USP 467 using Zebron™ ZB-624PLUS™ and ZB-WAXPLUS™ GC Columns

Technical Notes Residual Solvents Testing in Cannabis using Zebron™ ZB-624PLUS GC Column

Summary

Residual Solvents Testing in Cannabis using Zebron™ ZB-624PLUS GC Column

Technical Notes Solvent Purity Estimation Using a Zebron™ ZB-624PLUS™ GC Column

Summary

the present study, a Zebron ZB-624PLUS GC column is utilized to characterize the purity of solvents such as Acetone, Ethyl Acetate, Tetrahydrofuran, and n,n-Dimethylformamide. The selectivity and temperature resistance of ZB-624PLUS makes it a versatile stationary phase for both nonpolar and polar solvent purity characterization

Technical Notes Volatile Amine Analysis Using a Zebron™ ZB-624PLUS™GC Column

Summary

Volatile Amine Analysis Using a Zebron™ ZB-624PLUS™GC Column

Brochures ZB-FAME, The Fast FAME GC Column

Summary

Reduce traditional FAME run times by up to 75% and improve the separation of cis/trans FAME isomers while remaining compatible with AOAC, AOCS, and IOC regulatory methods!

Brochures Zebron 5 Phase Selection

Summary

3 Ways To Choose Your 5 Phase: #1 Review Column Characteristics #2 Choose by Application #3 Use GC Column Finder Online!

Brochures Zebron™ ZB-624PLUS Brochure

Summary

Zebron ZB-624plus is the optimal choice for the analysis of volatile compounds for Environmental, Pharmaceutical, Food, Cannabis, and Specialty Chemicals. This Brochure will provide all GC column benefits and applications notes for the 624plus new phase

Brochures Zebron Essentials for FAMEs, Smart Alternatives for the FAMEs Traditionalist

Summary

Looking for a cost effective alternative to other 88 and 23 phase columns? Make the switch to Zebron ZB-88 and ZB-23, the smart alternatives for the FAMEs traditionalist.

Part Number:AG0-7549

Description:Zebron™ ZB-5 w/Guardian Test Mix, 9 compounds @ 250 µg/mL each in Acetone, Ea

Technique:Gas Chromatography (GC)

Kit Type:

Kit Vial PartNo:

Kit Closure PartNo:

Certification:

Comment:

Competitor Alternative Parts:

Display Vial Details

Display Cap Details


 Search Results


Part
Number
Description Price