1Gensinoside-Re |
---|
2Gensinoside-Rb1 |
3Gensinoside-Rc |
Compound Name Ginsenoside Re |
CID 432449 |
Molecular Formula C48H82O18 |
Molecular Weight 947 |
No. Chiral Centers: 26 |
No. Hydrogen Bond Acceptors 18 |
No. Hydrogen Bond Donors 12 |
1Gensinoside-Re |
---|
2Gensinoside-Rb1 |
3Gensinoside-Rc |
Compound Name Ginsenoside Re |
CID 432449 |
Molecular Formula C48H82O18 |
Molecular Weight 947 |
No. Chiral Centers: 26 |
No. Hydrogen Bond Acceptors 18 |
No. Hydrogen Bond Donors 12 |
Column: | ||||||||||||
Brand Name: | ||||||||||||
Part No: | ||||||||||||
Phase Name: C18 | ||||||||||||
Elution Type: Gradient | ||||||||||||
Mobile Phase: A: Water B: Acetonitrile | ||||||||||||
Gradient Profile:
| ||||||||||||
Flow Rate: 1.5 mL/min | ||||||||||||
Temperature: 22°C | ||||||||||||
System: Agilent (HP) 1100 | ||||||||||||
Detection: UV-Vis Abs.-Variable Wave.(UV) @ 205 nm (22°C) | ||||||||||||
Sample Note: SecurityGuard™ Guard Cartridge System extends column lifetime.
- SecurityGuard Cartridges, Gemini C18 4 x 3.0mm, 10/Pk Part No.: AJ0-7597
- Holder Part No.: KJ0-4282 |