FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
EPA Method 552.2 on ZB-XLB (Carrier Gas: Helium)
16763
EPA 552
Caustics
Environmental

Applications

EPA Method 552.2 on ZB-XLB (Carrier Gas: Helium)
Analytes
1Chloroacetic acid
2Bromoacetic acid
3Dichloroacetic acid
4Dalapon
5Trichloroacetic acid
61,2,3-Triuchloropropane
7Bromochloroacetic acid
8Bromodichloroacetic acid
9Dibromoacetic acid
102,3-Dibromopropionic acid
11Chlorodibromoacetic acid
12Tribromoacetic acid
Compound Name
Chloroacetic Acid
CID
300
Molecular Formula
C2H3ClO2
Molecular Weight
94
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Details
Official Method: EPA 552
GC Conditions (App ID: 16763)
Injection:
Splitless @ 250°C, 1.0 μL
Oven Program:
40 °C to 60 °C @ 6 °C/min for 2.5 min to 100 °C @ 5 °C/min to 250 °C @ 30 °C/min for 4 min.
Carrier Gas:
Constant Flow Helium, 4.0 mL/min
Detection:
Electron Capture (ECD) (300°C)
Sample Notes:
Analyte concentration, 2 ppm
Similar Applications
search
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
High Temperature
Zebron ZB-35HT, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
High Temperature
Zebron ZB-35HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
High Temperature
Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
Standard
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
Application Specific
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
Application Specific
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Standard
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Standard
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Standard
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Standard