FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
BSA tryptic map in formic acid using Kinetex 2.6u C18 150x4.6mm
19121
Separation Mode: Reversed Phase
Reversed Phase
C18
HPLC
Peptide
Biochemical Compound / Nutrient

Applications

BSA tryptic map in formic acid using Kinetex 2.6u C18 150x4.6mm
Analytes
1Bovine Serum Albumin (BSA)

Analyte not found

Details
LC Conditions (App ID: 19121)
Column:
Brand Name:
Kinetex
Part No:
Phase Name:
C18
Elution Type:
Gradient
Mobile Phase:
A: Water with 0.1% formic acid
B: Acetonitrile with 0.1% formic acid
Gradient Profile:
Step No.Time(min)%A%B
10973
2305050
Flow Rate:
1 mL/min
Temperature:
0°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 214 nm (22°C)

Order Items Used in This Application

Similar Applications
search
No Data