For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Protein Deamidation Aeris WIDEPORE 3.6um XB-C8 150x4.6mm
19884
Separation Mode: Reversed Phase
Reversed Phase
WIDEPORE XB-C8
HPLC
Pharmaceutical/Biopharmaceutical
Life Science
Chromatographic Property
Biochemical Compound / Nutrient
Therapeutic / Clinical
Biochemical Compound / Nutrient
Biochemical Compound / Nutrient
Therapeutic / Clinical

Applications

Protein Deamidation Aeris WIDEPORE 3.6um XB-C8 150x4.6mm
Analytes
1Intact Insulin

Analyte not found

Details
LC Conditions (App ID: 19884)
Column:
Brand Name:
Part No:
Phase Name:
WIDEPORE XB-C8
Elution Type:
Gradient
Mobile Phase:
A: 0.1% TFA/ Water
B: 0.085%TFA/ Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
109010
3103565
Flow Rate:
1.2 mL/min
Temperature:
40°C
Detection:
UV-Vis Abs.-Diode Array (PDA) @ 214 nm (22°C)
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard ULTRA Cartridges, UHPLC WIDEPORE C8 for 4.6mm ID, 3/Pk Part No.: AJ0-8771 - Holder Part No.: AJ0-9000