For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Automated Extraction of Tricyclic Antidepressants by Perkin Elmer Multiprobe II
20937
Separation Mode: Reversed Phase
Reversed Phase
C18
HPLC
Antidepressive Agents, Tricyclic

Applications

Automated Extraction of Tricyclic Antidepressants by Perkin Elmer Multiprobe II
Analytes
1Doxepin
2DM-Doxepin
3Imipramine-d3
4Imipramine
5Desipramine-d3
6Desipramine
7Nortriptyline-d3
8Nortriptyline
9Amitriptyline
10Protriptyline-d3
11Protriptyline
12Clomipramine-d3
13Clomipramine
14DM-Clomipramine
Compound Name
Doxepin
CID
667477
Molecular Formula
C19H21NO
Molecular Weight
279
No. Hydrogen Bond Acceptors
2
Details
LC Conditions (App ID: 20937)
Column:
Brand Name:
Kinetex
Part No:
Phase Name:
C18
Elution Type:
Gradient
Mobile Phase:
A: 0.1% formic acid/water
B: 0.1% Formic acid/methanol
Gradient Profile:
Step No.Time(min)%A%B
106040
23.52080
342080
44.016040
556040
Flow Rate:
0.4 mL/min
Temperature:
22°C
Detection:
Mass Spectrometer (MS) (22°C)
Detector Info:
SCIEX API 4000™
Sample Note:
MS/MS Parameters Compound Q1 Q3 Dwell time DP EP CE CXP Protrip 264.2 191.1 35 60 10 35 10 Notrip 264.3 191.2 35 60 10 35 10 DM-Dox 266.2 107.1 25 60 10 35 10 Desip 267.2 208.2 35 60 10 35 10 Protrip-D3 267.2 191.1 35 60 10 35 10 Notrip-D3 267.3 191.2 35 60 10 35 10 Desip-D3 270.2 208.2 35 60 10 35 10 Amitrip 278.2 191.2 35 60 10 35 10 Dox 280.3 107.1 25 60 10 35 10 Imip 281.3 208.2 35 60 10 35 10 Imip-D3 284.2 208.1 35 60 10 35 10 DM-Clomip 301.2 242.2 35 60 10 35 10 Clomip 315.2 242.2 35 60 10 35 10 Clomip-D3 318.2 242.2 35 60 10 35 10 Ionization Parameters ESI in positive polarity Gas 1 50 Gas 2 50 CAD 8 Cur 20 IS 5500 Temp 600
Sample Preparation Details
Description:
Strata-X-Drug B 33 µm Polymeric Strong Cation, 30 mg / well, 96-Well Plates, 2/Pk
Part Number:
Pre Treatment Note:
To do % absolute recovery, the IS was spiked in the initial mobile phase in the reconstitution step
Sample PreTreatment:
To do % absolute recovery, the IS was spiked in the initial mobile phase in the reconstitution step
Wash 1:
100mM sodium acetate buffer (pH5.0)
Wash 2:
Methanol
Evaporation:
Evaporate to dryness
1
Shake
Methanol/ACN(5/50) + 2% ammonium hydroxide
1
Wash
100mM sodium acetate buffer (pH5.0)
2
Wash
Methanol

Order Items Used in This Application