For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Chiral Amphetamines Lux 3µm AMP 150x3mm
23631
Separation Mode: Chiral
Chiral
AMP
HPLC
Adrenergic Agents
Pharmaceutical/Biopharmaceutical
Clinical
Forensics/Toxicology
Therapeutic / Clinical
Therapeutic / Clinical
Therapeutic / Clinical
Therapeutic / Clinical

Applications

Chiral Amphetamines Lux 3µm AMP 150x3mm
Analytes
1R(-)-Amphetamine
2S(+)-Amphetamine
3R(-)-Methamphetamine
4S(+)-Methamphetamine
5Phentermine

Analyte not found

Details
LC Conditions (App ID: 23631)
Column:
Brand Name:
Part No:
Phase Name:
AMP
Elution Type:
Gradient
Mobile Phase:
A: 5 mM Ammonium Bicarbonate, adjusted to pH 11 with ammonium hydroxide
B: Methanol
Gradient Profile:
Step No.Time(min)%A%B
104060
2104060
311595
413595
513.14060
Flow Rate:
0.42 mL/min
Temperature:
22°C
Detection:
Tandem Mass Spec (MS-MS) (22°C)
Detector Info:
SCIEX 4500 QTRAP®

Order Items Used in This Application

Similar Applications
search