For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Chiral Amphetamines with Ephedrines & Pseudoephedrines on Lux 3µm AMP 150x3mm
23640
Separation Mode: Chiral
Chiral
AMP
HPLC
Serotonin Agents
Pharmaceutical/Biopharmaceutical
Clinical
Forensics/Toxicology
Therapeutic / Clinical
Therapeutic / Clinical
Therapeutic / Clinical
Therapeutic / Clinical

Applications

Chiral Amphetamines with Ephedrines & Pseudoephedrines on Lux 3µm AMP 150x3mm
Analytes
11S,2R(+)-Ephedrine
2R,R(-)-Pseudoephedrine
3S,S(+)-Pseudoephedrine
41R,2S(-)-Ephedrine
5R(-)-Amphetamine
6R(-)-Methamphetamine
7S(+)-Amphetamine
8S(+)-Methamphetamine
9Phentermine
10MDMA
11MDMA
Compound Name
D-Ephedrine
CID
9457
Molecular Formula
C10H15NO
Molecular Weight
165
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
2
Details
LC Conditions (App ID: 23640)
Column:
Brand Name:
Part No:
Phase Name:
AMP
Elution Type:
Gradient
Mobile Phase:
A: 5 mM Ammonium Bicarbonate, adjusted to pH 11 with ammonium hydroxide
B: Methanol
Gradient Profile:
Step No.Time(min)%A%B
104060
2104060
311595
416595
516.14060
Flow Rate:
0.42 mL/min
Temperature:
22°C
Detection:
Tandem Mass Spec (MS-MS) (22°C)
Detector Info:
SCIEX 4500 QTRAP®