For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
33 FAMEs by GC/FID on Zebron ZB-23
24249
Enzyme Inhibitors

Applications

33 FAMEs by GC/FID on Zebron ZB-23
Analytes
1C8:0
2C9:0
3C10:0
4C11:0
5C12:0
6C13:0
7C14:0
8C14:1 cis 9
9C15:0
10C15:1 cis 10
11C16:0
12C16:1 cis 9
13C17:0
14C17:1 cis 10
15C18:0
16C18:1 trans 9
17C18:1 cis 9
18C18:2 cis 9,12
19C18:3 cis 6,9,12
20C18:3 cis 9,12,15
21C20:0
22C20:1 cis 11
23C20:2 cis 11,14
24C20:3 cis 8,11,14
25C20:4 cis 5,8,11,14
26C20:3 cis 11,14,17
27C22:0
28C20:5 cis 5,8,11,14,17
29C22:1 cis 13
30C22:2 cis 13,16
31C24:0
32C22:6 cis 4,7,10,13,16,19
33C24:1 cis 15
Compound Name
Methyl Octanoate
CID
8091
Molecular Formula
C9H18O2
Molecular Weight
158
No. Hydrogen Bond Acceptors
2
Details
GC Conditions (App ID: 24249)
Injection:
Splitless @ 250°C, 1.0 μL
Oven Program:
50 °C hold 2 min to 180 °C @ 10 °C/min hold 5 min to 240 °C @ 5 °C/min
Carrier Gas:
Constant Flow Helium, 40.0 cm/sec
Detection:
Flame Ionization (FID) (300°C)
Sample Notes:
Recommended Accessories: Recommended Liner: Zebron PLUS Single Taper Z-Liner, 4 mm ID Liner Part No.: AG2-0A13-05 (for Agilent systems) Inlet Seal: AG0-8620 (Gold Plated Easy Seal) Septum: AG0-4696 (PhenoRed-400)