For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
GC/MS analysis of PAH in rubber and plastic on ZB-PAH
24508
Fluorescent Dyes
Food & Beverage
Specialty Chemical/Industrial
Environmental
Food and Beverage (incl. additives
contaminants)
Product / Trade Good

Applications

GC/MS analysis of PAH in rubber and plastic on ZB-PAH
Analytes
1Naphthalene-d8
2Naphthalene
32-methylnaphtalene
41-methylnaphthalene
5Acenaphthylene
6Acenaphthylene-d10
7aCENAPHTHENE
8Fluorene
9Phenanthrene-d10
10Phenanthrene
11Anthracene
12Fluoranthene
13Pyrene
14p-Terphenyl-d14
15Benzo(a)anthracene
16Chrysene-d12
17Chrysene
18Benzo(b)fluoranthene
19Benzo(k)fluoranthene
20Benzo(j)fluoranthene
21Benzo(e)pyrene
22Benzo(a)pyrene
23Perylene-d12
24Indeno(1,2,3-cd)pyrene
25Dibenzo(a,h)anthracen
26Benzo(g,h,i)perylene
Compound Name
Naphthalene-D8
CID
92148
Molecular Formula
C10H8
Molecular Weight
136
Details
GC Conditions (App ID: 24508)
Injection:
Splitless @ 290°C, 1.0 μL
Oven Program:
120°C for 1.0 min to 200°C @ 8°C/min for 0.5 min to 270°C @ 11°C/min to 300°C @ 2°C/min
Carrier Gas:
Constant Flow Helium, 52.0 cm/sec
Detection:
Mass Spectrometer (MS) @ 50 amu (250°C)
Sample Notes:
Sample Preparation: 1. Cut sample of rubber in 2 - 3mm pieces 2. Collect ~0.5g of cut pieces per extraction 3. Add 20mL of toluene 4. Add internal standard 5. Sonicate for 1 hour at 60°C 6. Cool and transfer aliquot to autosampler vial
Similar Applications
search
Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Application Specific
Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea
Application Specific
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Standard
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
High Temperature
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Standard
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Application Specific
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea
Standard
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
Standard
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Standard