For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Pindolol - USP Method
3288
Separation Mode: Reversed Phase
Reversed Phase
USP L01
C18(2)
HPLC
Antihypertensive Agents
Pharmaceutical
Therapeutic / Clinical

Applications

Pindolol - USP Method
Analytes
1Pindolol
Compound Name
Pindolol
CID
4828
Molecular Formula
C14H20N2O2
Molecular Weight
248
No. Chiral Centers:
1
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Details
Official Method: USP L01
LC Conditions (App ID: 3288)
Column:
Brand Name:
Part No:
Phase Name:
C18(2)
Elution Type:
Isocratic
Mobile Phase:
A: 50mM Sodium acetate, pH 5.0
B: Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
106535
Flow Rate:
1 mL/min
Temperature:
22°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 219 nm (22°C)
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Similar Applications
search
No Data