Region

GC Columns

Explore Our GC Product and Application Database

 

Zebron GC Columns

 

 

 

Guard Columns

Z-Guard Columns

Looking for an alternative to your current phase?

Use the GC Cross-Reference Chart »

Application-Specific GC Columns

 

Premier Zebron phases specially engineered to deliver the best results for specific application areas.

 

Robust columns with long lifetimes for high temperature bake outs up to 430 °C.

ZB-1HT Inferno

ZB-5HT Inferno

ZB-35HT Inferno

ZB-XLB-HT Inferno

Selectivities well-suited for low bleed.

ZB-5MSi

ZB-XLB

ZB-XLB-HT Inferno

 

See all MS Certified phases.

Bonded, solvent-rinseable phase for 100% aqueous stability.

ZB-WAXplus

 

 

NEW! Engineered specifically for SVOCs, acids, and amines.

ZB-SemiVolatiles

 

For analysis of pesticides, herbicides, and insecticides. Run EPA 8081 in ≤ 10 min.

ZB-MultiResidue-1

ZB-MultiResidue-2

Fast and accurate bioethanol, biodiesel, and simulated distillation analysis.

ZB-1XT SimDist

ZB-1HT Inferno

ZB-5HT Inferno

ZB-Bioethanol

Recommended for drugs of abuse and blood alcohol analysis.

ZB-Drug-1

ZB-BAC-1

ZB-BAC-2

 

 


Share Your Thoughts and Get A Free GC Troubleshooting Guide

 

Our innovation is fueled by your feedback! Take a minute to tell us what you think about our GC products and as a thank you get a FREE digital GC troubleshooting guide, which includes tips on improving:

  • Baseline problems
  • Peak shape issues
  • Ghost peaks
  • Irreproducible peak heights or areas
  • Retention time shifts
  • Resolution loss
  • Broad solvent fronts
  • Rapid column performance degradation

 

 
Share Your Thoughts & Get Your Guide »

 

« Go Back

 

GC Column Cross-Reference Chart by Phase

 

Our commitment to quality and innovation are what make Zebron GC columns well-suited for any application. Each and every column you receive is individually QC tested for efficiency, bleed, activity, and retention.

 

Phenomenex Zebron Composition Agilent Restek Supelco
NEW!
ZB-SemiVolatiles
5% Phenyl-Arylene
95% Dimethylpolysiloxane
DB-5ms Ultra Inert, HP-5ms Ultra Inert Rxi-5Sil MS, Rtx-5ms  
ZB-1 100% Dimethylpolysiloxane DB-1, DB-2887, DB-1 EVDX, HP-1, HP-101, HP-PONA, Ultra 1, CP-Sil 5 CB Rtx-1, Rtx-1PONA, Rtx-1 F&F SPB-1, SPB-1 TG, SE-30, MET-1, SPB-1 Sulfur, SPB-HAP
ZB-1ms 100% Dimethylpolysiloxane DB-1ms, HP-1ms, CP-Sil 5 CB MS, VF-1ms Rtx-1ms MDN-1, Equity-1
ZB-1HT Inferno 100% Dimethylpolysiloxane DB-1ht, CP-SimDist Rxi-1HT Petrocol 2887
ZB-1XT SimDist 100% Dimethylpolysiloxane CP-SimDist UltiMetal MXT-1HT SimDist  
ZB-5 5% Phenyl
95% Dimethylpolysiloxane
DB-5, HP-5, Ultra 2, HP-PAS-5, CP-Sil 8 CB Rtx-5 MDN-5, SPB-5, PTE-5, SE-54, PTA-5, Equity-5, Sac-5
ZB-5MSi 5% Phenyl
95% Dimethylpolysiloxane
DB-5, HP-5ms, HP-5msi Rtx-5ms, Rtx-5Amine, Rxi-5ms MDN-5S
ZB-5ms 5% Phenyl-Arylene
95% Dimethylpolysiloxane
DB-5ms, DB-5.625, DB-5ms EVDX, VF-5ms, CP-Sil 8 CB MS Rtx-5Sil MS, Rxi-5Sil MS  
ZB-5HT Inferno 5% Phenyl
95% Dimethylpolysiloxane
DB-5ht, VF-5ht Stx-5HT, XTI-5HT HT-5
ZB-35 35% Phenyl
65% Dimethylpolysiloxane
DB-35, DB-35ms, HP-35, HP-35ms Rtx-35, Rtx-35ms MDN-35, SPB-35, SPB-608
ZB-35HT Inferno 35% Phenyl
65% Dimethylpolysiloxane
Phenomenex Exclusive Innovation
ZB-50 50% Phenyl
50% Dimethylpolysiloxane
DB-17, DB-17hT, DB-17ms, DB-17 EVDX, HP-50+, CP-Sil 24 CB Rtx-50 SP-2250, SPB-17, SPB-50
ZB-624 6% Cyanopropylphenyl
94% Dimethylpolysiloxane
DB-1301, DB-624, DB-VRX, HP-VOC, CP-1301, CP-Select 624 CB Rtx-1301, Rtx-624 SPB-1301, SPB-624
ZB-1701 14% Cyanopropylphenyl
86% Dimethylpolysiloxane
DB-1701, CP-Sil 19 CB Rtx-1701 SPB-1701, Equity-1701
ZB-1701P 14% Cyanopropylphenyl
86% Dimethylpolysiloxane
DB-1701P    
ZB-WAX 100% Polyethylene Glycol DB-WAXetr, HP-INNOWax, CP-Wax 57 CB Rtx-WAX, Famewax, Stabilwax-DB Met-Wax, Omegawax
ZB-WAXplus 100% Polyethylene Glycol DB-WAX, CAM, HP-20M, Carbowax 20M, CP-Wax 52 CB Stabilwax SUPELCOWAX 10
ZB-FFAP Nitroterephthalic Acid Modified Polyethylene Glycol DB-FFAP,HP-FFAP, CP-Wax 58 (FFAP) CB, CP-FFAP CB Stabilwax-DA Nukol, SPB-1000
ZB-XLB Proprietary DB-XLB, VF-XMS Rtx-XLB MDN-12
ZB-XLB-HT Inferno Proprietary Phenomenex Exclusive Innovation
ZB-MultiResidue-1 Proprietary   Rtx-CLPesticides, Stx-CLPesticides  
ZB-MultiResidue-2 Proprietary   Rtx-CLPesticides2, Stx-CLPesticides2  
ZB-BAC-1 Proprietary DB-ALC1 Rtx-BAC1  
ZB-BAC-2 Proprietary DB-ALC2 Rtx-BAC2  
ZB-Drug-1 Proprietary Phenomenex Exclusive Innovation
ZB-Bioethanol Proprietary Phenomenex Exclusive Innovation

This section is, neither in terms of manufacturers nor in terms of their products, a complete list, and the accuracy of the data is not guaranteed. Small differences in dimensions of performance might be possible and slight adjustments to your application may be necessary.

 

Need cross-referencing or column selection assistance?

Contact Us »

 

Explore Popular GC Accessories

 


 

 
 
 
 

Need cross-referencing or accessory selection assistance?

Don't see your product listed here? We can help! We'll cross-reference your current part number for free.

 

Request Support »

Most Recent GC Tips

 

Basic Considerations for High Temp GC

In gas chromatography, elevated oven temperatures can be used to elute high boiling analytes faster with improved peak shapes, leading to better quantitation. Temperature ramps at the end of an analysis can be used to remove contaminants that may lead to various analytical problems including…

 

Read the full tip »
 

Video: How To Install the Cool-Lock Nut

The Cool-Lock Nut is designed to be a significant improvement over other commercial GC nuts in many ways. GC column installation is quick and easy, you can avoid burning your fingers because it cools with the oven, and it helps ensure more accurate, reproducible…

 

Read the full tip »
 

 


 

 

 

Don't see your topic covered here? Send us your question!

Request Your Topic »