For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
USP Sildenafil Citrate Tablet Assay USP - Sensitivity Solution 0.00035 mg/mL on Luna Omega 5 µm C18 150x4.6mm LC/UV- clone
26202
Separation Mode: Reversed Phase
Reversed Phase
USP
C18
HPLC
Pharmaceutical/Biopharmaceutical
Pharmaceutical
Therapeutic / Clinical

Applications

USP Sildenafil Citrate Tablet Assay USP - Sensitivity Solution 0.00035 mg/mL on Luna Omega 5 µm C18 150x4.6mm LC/UV- clone
Analytes
1Sildenafil citrate
Compound Name
Sildenafil
CID
5212
Molecular Formula
C22H30N6O4S
Molecular Weight
474
No. Hydrogen Bond Acceptors
8
No. Hydrogen Bond Donors
1
Details
Official Method: USP
LC Conditions (App ID: 26202)
Column:
Brand Name:
Part No:
Phase Name:
C18
Elution Type:
Isocratic
Mobile Phase:
A: Buffer (dilute 7 mL of triethylamine with water to 1 L. Stir and adjust with phosphoric acid to a pH of 3.0+/- 0.1), Methanol and Acetonitrile (58:25:17)
Gradient Profile:
Step No.Time(min)%A
120100
Flow Rate:
1.4 mL/min
Temperature:
30°C
System:
Agilent Technologies 1100 Series Agilent Technologies 1100 Series
Detection:
LC/UV (DAD, PDA) @ 290.0000000000 nm (nanometers) (30°C)
Sample Note:
0.00035 mg/mL

Order Items Used in This Application

Similar Applications
search
Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase
Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase
Luna Omega 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase
Luna Omega 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
Reversed Phase