For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Pharmaceuticals
10138
Separation Mode: Reversed Phase
Reversed Phase
C8
HPLC
Anti-Infective Agents
Pharmaceutical
Therapeutic / Clinical

Applications

Pharmaceuticals
Analytes
1Oxycodone
2Aspirin
3Salicylic acid
Compound Name
Oxycodone
CID
5284603
Molecular Formula
C18H21NO4
Molecular Weight
315
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
1
Details
LC Conditions (App ID: 10138)
Column:
Brand Name:
Part No:
Phase Name:
C8
Elution Type:
Isocratic
Mobile Phase:
A: 0.025 M Phosphate buffer, pH 2.2 w/ H3PO4
B: Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
108515
Flow Rate:
1.5 mL/min
Temperature:
22°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 220 nm (22°C)
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Similar Applications
search
No Data