FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
PEGylated Insulin on Jupiter® 300 C4, C18 and Two Experimental Columns
16193
Separation Mode: Reversed Phase
Reversed Phase
C4
HPLC
Pharmaceutical/Biopharmaceutical
Life Science
Biopharmaceutical
Therapeutic / Clinical

Applications

PEGylated Insulin on Jupiter® 300 C4, C18 and Two Experimental Columns
Analytes
1PEGylated Insulin

Analyte not found

Details
LC Conditions (App ID: 16193)
Column:
Brand Name:
Part No:
Phase Name:
C4
Elution Type:
Gradient
Mobile Phase:
A: 0.1% TFA and 2% ACN in Water
B: 70/20% ACN/IPA, 0.08% TFA in Water
Gradient Profile:
Step No.Time(min)%A%B
108515
2253070
Flow Rate:
1 mL/min
Temperature:
45°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 214 nm (22°C)
Sample Note:
Reversed phase of PEGylated Insulin run on listed columns. Note the reduced resolution for the Jupiter C18 and EXP 2 columns when compared to the Jupiter C4 column. Although it is difficult to visualize, the Jupiter actully has better resolution of PEGylated forms than the EXP1 column.