FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Pain Panel Mix-41 in Human Urine on Luna 3u, PFP(2), 50x3 by LC-MS/MS
20594
Separation Mode: Reversed Phase
Reversed Phase
PFP(2)
HPLC
Analgesics, Opioid
Clinical
Forensics/Toxicology
Chemical Compound
Therapeutic / Clinical
Therapeutic / Clinical

Applications

Pain Panel Mix-41 in Human Urine on Luna 3u, PFP(2), 50x3 by LC-MS/MS
Analytes
1Morphine
2Oxymorphone
3Hydromorphone
4Codeine
5Oxycodone
6Amphetamine
7Naltrexone
86-MAM
9Hydrocodone
10Methamphetamine
11MDA
12Benzoylecgonine
13Naloxone
14MDMA
15MDEA
16Norfentanyl
17Meprobamate
18Tramadol
19Normeperidine
20Meperidine
21PCP
22alpha-Hydroxyalprazolam
23Lorazepam
24Norbuprenorphine
25Oxazepam
26Carisoprodol
27Clonazepam
28EDDP
29Alprazolam
30Temazepam
31Flunitrazepam
32Nordiazepam
33Norpropoxyphene
34Flurazepam
35Fentanyl
36Midazolam
37Diazepam
38Methadone
39Sufentanil
40Propoxyphene
41Buprenorphine
Compound Name
Morphine
CID
5288826
Molecular Formula
C17H19NO3
Molecular Weight
285
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
2
Details
LC Conditions (App ID: 20594)
Column:
Brand Name:
Part No:
Phase Name:
PFP(2)
Elution Type:
Gradient
Mobile Phase:
A: 10 mM Ammonium formate
B: Methanol
Gradient Profile:
Step No.Time(min)%A%B
10955
25.5595
37595
47.1955
59955
Flow Rate:
500 µL/min
Temperature:
40°C
Detection:
Mass Spectrometer (MS) (22°C)
Detector Info:
SCIEX API 4000™
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, PFP 4 x 2.0mm ID, 10/Pk Part No.: AJ0-8326 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Similar Applications
search
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
Reversed Phase
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea