For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Extraction of Parabens from Baby Wash using Novum SLE 12cc Tube & Kinetex 5u EVO C18, 100x3.0
22848
Separation Mode: Reversed Phase
Reversed Phase
EVO C18
HPLC
Preservatives, Pharmaceutical
Personal Care/Consumer Products
Personal Healthcare / Cosmetic
Product / Trade Good

Applications

Extraction of Parabens from Baby Wash using Novum SLE 12cc Tube & Kinetex 5u EVO C18, 100x3.0
Analytes
1Methyl paraben
2Ethyl paraben
3Propyl paraben
4Butyl paraben
Compound Name
Methyl Paraben
CID
7456
Molecular Formula
C8H8O3
Molecular Weight
152
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Details
LC Conditions (App ID: 22848)
Column:
Brand Name:
Kinetex
Part No:
Phase Name:
EVO C18
Elution Type:
Gradient
Mobile Phase:
A: 10% acetonitrile in water
B: Acetonitrile
Gradient Profile:
Step No.Time(min)%A%B
109010
247030
356040
466040
Flow Rate:
1.5 mL/min
Temperature:
22°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 254 nm (22°C)
Sample Note:
Analytes 1. Methyl paraben 2. Ethyl paraben 3. Propyl paraben 4. Butyl paraben Novum SLE 12cc Tube 8B-S138-KDG Novum SLE 12cc Tube Extraction Procedure Sample pre-treatment 0.5 ± 0.05 g spiked Aveeno Baby (Wash & Shampoo) sample Add 1.25 mL acetone Add 0.6 ml 1% Nacl solution Vortex for 30 secs Wait 30 secs till the emulsion dissipates Centrifuge for 10 mins at 3000 rpm Collect the supernatant and proceed to load Sample loading "Load the sample from pre-treatment step above onto the Novum SLE cartridge and apply a short and gentle pulse of vacuum (~ 5" of Hg for 5-10 sec or until the sample has completely entered the media). "Wait for 5 minutes. Elution "Dispense 10 mL of ethylacetate onto the SLE media and allow the solvent to elute by gravity for 10 mins and collect the eluant. "Apply vacuum at 5"-10"of Hg to complete the extraction. NOTE: Prolonged application of vacuum will result in elution of body wash out of the SLE media and into the final extracted solvent. Dry down "Evaporate the final extract to complete dryness under slow stream of N2 at 45°C Reconstitute "Reconstitute the dry residue in 0.5 mL of methanol "Centrifuge for 5 mins at 6000 rpm "Collect supernatant to shoot on HPLC

Order Items Used in This Application

Similar Applications
search
Kinetex 5 µm EVO C18 100 Å, LC Column 100 x 3.0 mm, Ea
Reversed Phase