For security purposes
FOR SECURITY PURPOSES - because Internet Explorer is no longer supported by Microsoft, we suggest that you interact with our secure site through one of our supported browsers - Google Chrome, Firefox, or MS Edge. If you continue to use this website with Internet Explorer you do so at your own risk and you may encounter problems.
Applications
Diuretics
5405
Separation Mode: Reversed Phase
Reversed Phase
RP-18
HPLC
Antihypertensive Agents
Pharmaceutical
Therapeutic / Clinical

Applications

Diuretics
Analytes
1Chlorothiazide
2Hydrochlorothiazide
3Cyclothiazide
4Bendroflumethiazide
Compound Name
Chlorothiazide
CID
2720
Molecular Formula
C7H6ClN3O4S2
Molecular Weight
295
No. Hydrogen Bond Acceptors
7
No. Hydrogen Bond Donors
2
Details
LC Conditions (App ID: 5405)
Column:
Brand Name:
Part No:
Phase Name:
RP-18
Elution Type:
Isocratic
Mobile Phase:
A: Acetonitrile
B: Water
Gradient Profile:
Step No.Time(min)%A%B
103070
Flow Rate:
1.5 mL/min
Temperature:
22°C
Detection:
UV-Vis Abs.-Variable Wave.(UV) @ 220 nm (22°C)
Sample Note:
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Similar Applications
search
No Data