Aflatoxins
LC Conditions
Column
Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Prodigy
Part No
00F-4097-E0
Phase Name
ODS-3
Elution Type
Isocratic
Mobile Phase
A: Water
B: Acetonitrile
C: Methanol
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
68
24
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
Fluorescence (FLUOR) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Aflatoxin M2
- 2. Aflatoxin M1
-OEChem-06211003162D<br><br> 38 42 0 1 0 0 0 0 0999 V2000<br> 2.0000 -0.4776 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5229 -1.5894 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1100 0.8296 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3191 1.2569 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0672 -1.7846 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4252 2.5217 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2133 2.7846 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5229 0.0201 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.9393 -0.7846 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.4691 -0.2846 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9393 0.8176 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.5106 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4691 -1.2846 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3351 0.2154 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2012 -0.2846 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1112 0.2222 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3351 -1.7846 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2012 -1.2846 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0943 -0.1028 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1192 1.2638 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7087 0.7307 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1072 1.5736 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2171 1.7846 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0672 -2.7846 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5742 -1.2857 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4753 1.1291 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6858 1.3834 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.8704 1.1169 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3834 0.4454 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3351 -2.4046 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8573 1.3958 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8389 -0.6677 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6293 -0.4161 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.1663 0.3125 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.1727 1.1419 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.4472 -2.7846 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0672 -3.4046 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6872 -2.7846 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 12 1 0 0 0 0<br> 2 9 1 0 0 0 0<br> 2 13 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 3 31 1 0 0 0 0<br> 4 14 1 0 0 0 0<br> 4 23 1 0 0 0 0<br> 5 18 1 0 0 0 0<br> 5 24 1 0 0 0 0<br> 6 22 2 0 0 0 0<br> 7 23 2 0 0 0 0<br> 8 9 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 11 1 0 0 0 0<br> 9 25 1 0 0 0 0<br> 10 13 1 0 0 0 0<br> 10 14 2 0 0 0 0<br> 11 12 1 0 0 0 0<br> 11 26 1 0 0 0 0<br> 11 27 1 0 0 0 0<br> 12 28 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 13 17 2 0 0 0 0<br> 14 15 1 0 0 0 0<br> 15 16 1 0 0 0 0<br> 15 18 2 0 0 0 0<br> 16 19 1 0 0 0 0<br> 16 20 2 0 0 0 0<br> 17 18 1 0 0 0 0<br> 17 30 1 0 0 0 0<br> 19 21 1 0 0 0 0<br> 19 32 1 0 0 0 0<br> 19 33 1 0 0 0 0<br> 20 22 1 0 0 0 0<br> 20 23 1 0 0 0 0<br> 21 22 1 0 0 0 0<br> 21 34 1 0 0 0 0<br> 21 35 1 0 0 0 0<br> 24 36 1 0 0 0 0<br> 24 37 1 0 0 0 0<br> 24 38 1 0 0 0 0<br>M END
Compound Name
Aflatoxin M2
CID
23318
Molecular Formula
C17H14O7
Molecular Weight
330
No. Hydrogen Bond Acceptors
7
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Multi-Class Screening of 243 Mycotoxins by LC/MS/MS
Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
20027
Reversed Phase
Aflatoxins
Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea
10129