Pharmaceuticals

Pharmaceuticals
LC Conditions
Column

Prodigy 5 µm C8 150 Å, LC Column 150 x 4.6 mm, Ea

Brand

Prodigy

Part No

00F-3301-E0

Phase Name

C8

Elution Type

Isocratic

Mobile Phase

A: 0.025 M Phosphate buffer, pH 2.2 w/ H3PO4

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

85

15

Flow Rate

1.50 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Prodigy 5 µm C8 150 Å, LC Column 150 x 4.6 mm, Ea
00F-3301-E0

Prodigy 5 µm C8 150 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Oxycodone
  • 2. Aspirin
  • 3. Salicylic acid
-OEChem-05081000432D<br><br> 44 48  0     1  0  0  0  0  0999 V2000<br>    2.2314   -0.4472    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1561   -2.2171    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.9021    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.9022    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1607   -1.4511    0.0000 N   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.6897   -0.9755    0.0000 C   0  0  1  0  0  0  0  0  0  0  0  0<br>    4.5133   -1.4511    0.0000 C   0  0  1  0  0  0  0  0  0  0  0  0<br>    5.3370   -0.9755    0.0000 C   0  0  1  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.4511    0.0000 C   0  0  2  0  0  0  0  0  0  0  0  0<br>    4.2392   -0.2781    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.6897   -0.0245    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5133   -2.4021    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3370   -0.0245    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5918   -0.2781    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5133    0.4511    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.6897   -2.8777    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.4021    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.4511    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8418   -2.1832    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5133    1.4022    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.4022    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.6897    1.8777    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    2.9021    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6284   -1.7740    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0496   -1.6875    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3760    0.3266    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.6795   -0.0113    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7254   -2.9848    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1239   -2.2945    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.9476   -0.1321    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5490    0.5581    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1840   -0.0943    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4989    0.3349    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.2912   -3.3526    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0882   -3.3526    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2638   -2.8277    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3879   -2.6055    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.2641   -2.6371    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.2957   -1.7609    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.0503    1.7122    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.6897    2.4977    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6200    2.9021    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    3.5222    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.3800    2.9021    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  1  0  0  0  0<br>  1 18  1  0  0  0  0<br>  7  2  1  1  0  0  0<br>  2 36  1  0  0  0  0<br>  3 17  2  0  0  0  0<br>  4 21  1  0  0  0  0<br>  4 23  1  0  0  0  0<br>  5  8  1  0  0  0  0<br>  5 14  1  0  0  0  0<br>  5 19  1  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6  9  1  0  0  0  0<br>  6 10  1  1  0  0  0<br>  6 11  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>  8 13  1  0  0  0  0<br>  8 24  1  6  0  0  0<br>  9 17  1  0  0  0  0<br>  9 25  1  1  0  0  0<br> 10 14  1  0  0  0  0<br> 10 26  1  0  0  0  0<br> 10 27  1  0  0  0  0<br> 11 15  2  0  0  0  0<br> 11 18  1  0  0  0  0<br> 12 16  1  0  0  0  0<br> 12 28  1  0  0  0  0<br> 12 29  1  0  0  0  0<br> 13 15  1  0  0  0  0<br> 13 30  1  0  0  0  0<br> 13 31  1  0  0  0  0<br> 14 32  1  0  0  0  0<br> 14 33  1  0  0  0  0<br> 15 20  1  0  0  0  0<br> 16 17  1  0  0  0  0<br> 16 34  1  0  0  0  0<br> 16 35  1  0  0  0  0<br> 18 21  2  0  0  0  0<br> 19 37  1  0  0  0  0<br> 19 38  1  0  0  0  0<br> 19 39  1  0  0  0  0<br> 20 22  2  0  0  0  0<br> 20 40  1  0  0  0  0<br> 21 22  1  0  0  0  0<br> 22 41  1  0  0  0  0<br> 23 42  1  0  0  0  0<br> 23 43  1  0  0  0  0<br> 23 44  1  0  0  0  0<br>M  END
Compound Name

Oxycodone

CID

5284603

Molecular Formula

C18H21NO4

Molecular Weight

315

No. Hydrogen Bond Acceptors

5

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS

Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea

25864

Reversed Phase

Extraction of Opiates in Human Serum Using Strata-X PRO and a Kinetex 2.6 µm Biphenyl LC Column

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

25490

Reversed Phase

Pain Panel from Urine using Strata DE SLE and a Kinetex Biphenyl Core-Shell LC Column

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

24555

Reversed Phase

7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea

23560

Reversed Phase

Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

23445

Reversed Phase

Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm

Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

23444

Reversed Phase

Drugs of Abuse by LCMS using Luna Omega 1.6u C18 50x2.1mm

Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA

23443

Reversed Phase

Fast Pain Panel ESI+

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea

23384

Improved Performance

ZB-5MSplus Drugs of Abuse

Zebron ZB-5MSplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, EA

23258

Reversed Phase

Opiates at high pH using Kinetex 5u EVO C18 50 x 2.1 mm

Kinetex 5 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

22715

Reversed Phase

Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

22122

Reversed Phase

Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22121

Reversed Phase

Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm

Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22120

Reversed Phase

Pain Panel Opiates using Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22108

Reversed Phase

Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22104

Reversed Phase

Opiates using Kinetex 2.6u Biphenyl 50x2.1mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

21972

Reversed Phase

Pain Panel using Strata-X-Drug B and Kinetex Phenyl-Hexyl 2.6u 50x4.6mm

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea

20847

Reversed Phase

Pain Panel Opiates by LC/MS using Kinetex 2.6u C18 50x2.1mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20692

Reversed Phase

Pain Panel/Drug Screening by LCMS using Kinetex 2.6u C18 50x3.0mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 3 mm, Ea

20689

Reversed Phase

Pain Panel Mix-41 in Human Urine on Luna 3u, PFP(2), 50x3 by LC-MS/MS

Luna 3 µm PFP(2) 100 Å, LC Column 50 x 3 mm, Ea

20594

Reversed Phase

LC/MS/MS of Extended Opiates from urine using Strata-X-Drug B on a Kinetex C18 2.6µm, 50x2.1mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19705

Reversed Phase

Pain Panel on Kinetex C18 2.6µm 50 x 2.1 mm by LC/MS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19177

Reversed Phase

Pain Panel with and without sample focusing on Kinetex C18 2.6µm 50 x 2.1 mm by LC/MS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19167

Reversed Phase

NIDA-5 Extracted from Human Urine at Cutoff - Kinetex 2.6µm C18 50 x 2.1mm ID by LCMSMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18851

Reversed Phase

Pain panel extracted from human urine at cutoff - Kinetex C18 2.6µm 50x2.1mm LCMSMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18850

Reversed Phase

Extraction of Opiates-NIDA5 Using Strata X-C on Kinetex 2.6µm C18 50 x 2.1mm ID by LCMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18846

Reversed Phase

Extraction of Healthcare Opiates using strata X-C on Kinetex 2.6µm C18 50 x 2.1mm ID by LC/MS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18716

Reversed Phase

Healthcare Opiates on Kinetex 2.6µm C18 50 x 2.1 mm ID by LC/MS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18715

Application Specific

Expanded healthcare opiates (propyl derivatives) from urine by Screen C on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18200

Application Specific

Healthcare opiates (propyl derivatives) by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18181

Healthcare Opiates from Urine by Screen C on a ZB-5MSi

17908

Application Specific

Healthcare Opiates from Urine by Screen C on a ZB-Drug-1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

17907

Application Specific

Healthcare Opiates by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

17899

Opiates expanded run by MSD on a ZB-5MSi

16555

Standard

Opiates expanded run by MSD on a ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16554

Standard

Opiates on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14788

Reversed Phase

Opiates on Synergi Max-RP

Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea

14253

Reversed Phase

Opiates on Synergi Polar-RP

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea

14252

Reversed Phase

Opiates on Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea

14251