Prodigy PH-3 I
LC Conditions
Column
Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Prodigy
Part No
00F-4298-E0
Phase Name
Phenyl-3 (PH-3)
Elution Type
Isocratic
Mobile Phase
A: Acetonitrile
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
45
55
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Phenyl 4 x 3.0mm, 10/Pk Part No.: AJ0-4351 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Ethylbenzene
- 2. Naphthalene
-OEChem-06211003152D<br><br> 18 18 0 0 0 0 0 0 0999 V2000<br> 2.8660 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6540 1.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2554 1.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0420 1.2131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4220 2.2869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 2 1 0 0 0 0<br> 1 5 1 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 10 1 0 0 0 0<br> 2 3 2 0 0 0 0<br> 2 4 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 11 1 0 0 0 0<br> 4 7 2 0 0 0 0<br> 4 12 1 0 0 0 0<br> 5 13 1 0 0 0 0<br> 5 14 1 0 0 0 0<br> 5 15 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 16 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 17 1 0 0 0 0<br> 8 18 1 0 0 0 0<br>M END
Compound Name
Ethylbenzene
CID
7500
Molecular Formula
C8H10
Molecular Weight
106
Similar Applications
Reversed Phase
Alkylsulfonate Esters on Luna Omega Polar C18 - TFA
Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA
25640
Reversed Phase
5a) Sulfonic Acid Esters on Luna Omega Polar C18 - formic acid
Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA
25604
Reversed Phase
4b) Sulfonic Acid Esters on Luna Omega Polar C18 - ammonium formate
Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA
25602
Application Specific
ASTM 6730 on ZB-PONA 100m x 0.25mm x 0.5um with ZB-PONA tuning 5m x 0.25mm x 1.0mm
Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea
25558
Application Specific
Aromatics Marker Standards on ZB-DHA-PONA 100m x 0.25mm x 0.5um
Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea
25309
Reversed Phase
ABN mix at low pH using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22735
Reversed Phase
ABN mix at high pH using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22733
Reversed Phase
ABN mix at neutral pH using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22732
Standard
Bioethanol by MSD on a ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
16657
Application Specific
Bioethanol by MSD on ZB-Bioethanol
Zebron ZB-Bioethanol, GC Cap. Column 30 m x 0.25 mm x 1.00 µm, Ea
16654
Improved Performance
USP 467 Procedure B - Class 2 Mix A by GC/FID on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16353
Standard
USP 467 Procedure A - Class 2 Mix A by GC/FID on ZB-624
Zebron ZB-624, GC Cap. Column 30 m x 0.32 mm x 1.80 µm, Ea
16349
Application Specific
BTEXs on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16254
Application Specific
BTEXs on ZB-MR2
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea
16253
Standard
Ylang Ylang Oill on ZB-1
Zebron ZB-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16246
Standard
ASTM Method D3798: Analysis of p-Xylene on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea
16219
Standard
ASTM Method D3798: Analysis of p-Xylene on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
16218
Standard
ASTM Method D5060: Determining Impurities in High Purity Ethylbenzene on ZB-FFAP
Zebron ZB-FFAP, GC Cap. Column 50 m x 0.32 mm x 0.50 µm, Ea
16145
Standard
ASTM Method D5135-95: Impurities in Styrene (Fast Analysis) on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
16143
Standard
ASTM Method D5135-95: Analysis of Styrene on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
16142
Standard
ASTM Method D2306-96: Universal Aromatic Solvent Analysis on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 60 m x 0.32 mm x 0.50 µm, Ea
16141
Improved Performance
ASTM Method D5135-95: Solvent Analysis on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16140
Standard
ASTM Method D5135-95: Solvent Analysis on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16139
Improved Performance
Solvents on ZB-WAXplus 30x0.25x0.25
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15926
Standard
EPA Method 8260 - Volatile Organic Analysis on Zebron ZB-624 20m x 0.18mm x 1.00um
Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea
15866
Improved Performance
p-Xylene Purity on ZB-WAX Plus 30m x 0.53mm x 1.00um
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea
15865
Improved Performance
p-Xylene Purity on ZB-WAX Plus 30x0.25x0.25
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15810
Standard
EPA Method 8260B: Volatile Organic Analysis on ZB-624
Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea
15697
Standard
p-Xylene Purity on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea
14941
Standard
Unleaded Gasoline - Pure on ZB-1
Zebron ZB-1, GC Cap. Column 60 m x 0.25 mm x 1.00 µm, Ea
14940
Standard
BTEX ZB-50 30x0.32x0.5
Zebron ZB-50, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
14903
Standard
BTEX ZB5 30x0.32x0.25
Zebron ZB-5, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
14902
Standard
BTEX ZB1 100x0.25x0.5
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14901
Standard
BTEX in Under Six Minutes on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
14895
Standard
Industrial Solvents on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea
14809
Standard
Industrial Solvents on ZB-WAX 30x0.25x0.25
Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14808
Standard
Industrial Solvents on ZB-624 60x0.32x1.8
Zebron ZB-624, GC Cap. Column 60 m x 0.32 mm x 1.80 µm, Ea
14807
Standard
PONA: Naphtha on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14804
Standard
PONA: Retention Markers on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14803
Standard
PONA: FCC on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14802
Standard
PONA: Blended Fuel 1 on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14801
Standard
PONA: Alkylate Fraction on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14800
Standard
EPA Method 8260: Volatile Organics on ZB-624
Zebron ZB-624, GC Cap. Column 60 m x 0.25 mm x 1.40 µm, Ea
14783
Standard
Volatile Organics by GC/MS (EPA Method 8260B)
Zebron ZB-624, GC Cap. Column 60 m x 0.53 mm x 3.00 µm, Ea
14441
Standard
EPA Method 624 CLP
Zebron ZB-624, GC Cap. Column 30 m x 0.53 mm x 3.00 µm, Ea
14323
Standard
Gasoline Range Organics
Zebron ZB-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
1265