Prodigy PH-3 I

Prodigy PH-3 I
LC Conditions
Column

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Prodigy

Part No

00F-4298-E0

Phase Name

Phenyl-3 (PH-3)

Elution Type

Isocratic

Mobile Phase

A: Acetonitrile

B: Water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

45

55

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Phenyl 4 x 3.0mm, 10/Pk Part No.: AJ0-4351 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4298-E0

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Ethylbenzene
  • 2. Naphthalene
-OEChem-06211003152D<br><br> 18 18  0     0  0  0  0  0  0999 V2000<br>    2.8660    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6540    1.8326    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2554    1.1423    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0420    1.2131    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    2.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4220    2.2869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  2  1  0  0  0  0<br>  1  5  1  0  0  0  0<br>  1  9  1  0  0  0  0<br>  1 10  1  0  0  0  0<br>  2  3  2  0  0  0  0<br>  2  4  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3 11  1  0  0  0  0<br>  4  7  2  0  0  0  0<br>  4 12  1  0  0  0  0<br>  5 13  1  0  0  0  0<br>  5 14  1  0  0  0  0<br>  5 15  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6 16  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 17  1  0  0  0  0<br>  8 18  1  0  0  0  0<br>M  END
Compound Name

Ethylbenzene

CID

7500

Molecular Formula

C8H10

Molecular Weight

106

Similar Applications

Reversed Phase

Alkylsulfonate Esters on Luna Omega Polar C18 - TFA

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

25640

Reversed Phase

5a) Sulfonic Acid Esters on Luna Omega Polar C18 - formic acid

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

25604

Reversed Phase

4b) Sulfonic Acid Esters on Luna Omega Polar C18 - ammonium formate

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

25602

Application Specific

ASTM 6730 on ZB-PONA 100m x 0.25mm x 0.5um with ZB-PONA tuning 5m x 0.25mm x 1.0mm

Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea

25558

Application Specific

Aromatics Marker Standards on ZB-DHA-PONA 100m x 0.25mm x 0.5um

Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea

25309

Reversed Phase

ABN mix at low pH using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22735

Reversed Phase

ABN mix at high pH using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22733

Reversed Phase

ABN mix at neutral pH using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22732

Standard

Bioethanol by MSD on a ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

16657

Application Specific

Bioethanol by MSD on ZB-Bioethanol

Zebron ZB-Bioethanol, GC Cap. Column 30 m x 0.25 mm x 1.00 µm, Ea

16654

Improved Performance

USP 467 Procedure B - Class 2 Mix A by GC/FID on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16353

Standard

USP 467 Procedure A - Class 2 Mix A by GC/FID on ZB-624

Zebron ZB-624, GC Cap. Column 30 m x 0.32 mm x 1.80 µm, Ea

16349

Application Specific

BTEXs on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16254

Application Specific

BTEXs on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

16253

Standard

Ylang Ylang Oill on ZB-1

Zebron ZB-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16246

Standard

ASTM Method D3798: Analysis of p-Xylene on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea

16219

Standard

ASTM Method D3798: Analysis of p-Xylene on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16218

Standard

ASTM Method D5060: Determining Impurities in High Purity Ethylbenzene on ZB-FFAP

Zebron ZB-FFAP, GC Cap. Column 50 m x 0.32 mm x 0.50 µm, Ea

16145

Standard

ASTM Method D5135-95: Impurities in Styrene (Fast Analysis) on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

16143

Standard

ASTM Method D5135-95: Analysis of Styrene on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16142

Standard

ASTM Method D2306-96: Universal Aromatic Solvent Analysis on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 60 m x 0.32 mm x 0.50 µm, Ea

16141

Improved Performance

ASTM Method D5135-95: Solvent Analysis on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16140

Standard

ASTM Method D5135-95: Solvent Analysis on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16139

Improved Performance

Solvents on ZB-WAXplus 30x0.25x0.25

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15926

Standard

EPA Method 8260 - Volatile Organic Analysis on Zebron ZB-624 20m x 0.18mm x 1.00um

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

15866

Improved Performance

p-Xylene Purity on ZB-WAX Plus 30m x 0.53mm x 1.00um

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

15865

Improved Performance

p-Xylene Purity on ZB-WAX Plus 30x0.25x0.25

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15810

Standard

EPA Method 8260B: Volatile Organic Analysis on ZB-624

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

15697

Standard

p-Xylene Purity on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

14941

Standard

Unleaded Gasoline - Pure on ZB-1

Zebron ZB-1, GC Cap. Column 60 m x 0.25 mm x 1.00 µm, Ea

14940

Standard

BTEX ZB-50 30x0.32x0.5

Zebron ZB-50, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

14903

Standard

BTEX ZB5 30x0.32x0.25

Zebron ZB-5, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

14902

Standard

BTEX ZB1 100x0.25x0.5

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14901

Standard

BTEX in Under Six Minutes on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

14895

Standard

Industrial Solvents on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

14809

Standard

Industrial Solvents on ZB-WAX 30x0.25x0.25

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14808

Standard

Industrial Solvents on ZB-624 60x0.32x1.8

Zebron ZB-624, GC Cap. Column 60 m x 0.32 mm x 1.80 µm, Ea

14807

Standard

PONA: Naphtha on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14804

Standard

PONA: Retention Markers on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14803

Standard

PONA: FCC on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14802

Standard

PONA: Blended Fuel 1 on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14801

Standard

PONA: Alkylate Fraction on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14800

Standard

EPA Method 8260: Volatile Organics on ZB-624

Zebron ZB-624, GC Cap. Column 60 m x 0.25 mm x 1.40 µm, Ea

14783

Standard

Volatile Organics by GC/MS (EPA Method 8260B)

Zebron ZB-624, GC Cap. Column 60 m x 0.53 mm x 3.00 µm, Ea

14441

Standard

EPA Method 624 CLP

Zebron ZB-624, GC Cap. Column 30 m x 0.53 mm x 3.00 µm, Ea

14323

Standard

Gasoline Range Organics

Zebron ZB-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

1265