Aromatic Compounds
LC Conditions
Column
Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Prodigy
Part No
00F-4298-E0
Phase Name
Phenyl-3 (PH-3)
Elution Type
Isocratic
Mobile Phase
A: Acetonitrile
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
65
35
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Phenyl 4 x 3.0mm, 10/Pk Part No.: AJ0-4351 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Acetophenone
- 2. Benzene
- 3. Toluene
- 4. Naphthalene
-OEChem-06211003152D<br><br> 17 17 0 0 0 0 0 0 0999 V2000<br> 2.0000 1.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0420 1.2131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4220 2.2869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 5 2 0 0 0 0<br> 2 3 2 0 0 0 0<br> 2 4 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 4 7 2 0 0 0 0<br> 4 11 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 12 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 13 1 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 15 1 0 0 0 0<br> 9 16 1 0 0 0 0<br> 9 17 1 0 0 0 0<br>M END
Compound Name
Acetophenone
CID
7410
Molecular Formula
C8H8O
Molecular Weight
120
No. Hydrogen Bond Acceptors
1
Similar Applications
Application Specific
EPA Method 8270D on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
20582
Application Specific
Fast EPA Method 8270D on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea
20572
Reversed Phase
Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea
19812
Reversed Phase
Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea
19811
Reversed Phase
Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea
19810
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18803
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18802
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18801
High Temperature
EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
18785
Application Specific
Drug screen by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18175
Standard
EPA Method 8270C on ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16584
EPA Method 8270C ZB-5MSi
16413
Application Specific
EPA Method 8270C on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16275
Improved Performance
Industrial Chemicals: Ketones on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea
16238
Standard
Industrial Chemicals: Ketones on ZB-624
Zebron ZB-624, GC Cap. Column 30 m x 0.53 mm x 3.00 µm, Ea
16232
Standard
Common Drug Screen on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
16009
Common Drug Screen on ZB-1MS
16008
Standard
EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea
15696
Standard
EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
15695
Standard
EPA Method 8270C on ZB-5MS 30x0.25x0.25
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14953
Standard
EPA Method 8270C on Guardian on ZB-5
Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14945