Mercury - Decreased analysis time #2

Mercury - Decreased analysis time #2
LC Conditions
Column

Luna 3 µm C18(2) 100 Å, LC Column 30 x 4.6 mm, Ea

Brand

Luna

Part No

00A-4251-E0

Phase Name

C18(2)

Elution Type

Isocratic

Mobile Phase

A: Water

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

50

50

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 3 µm C18(2) 100 Å, LC Column 30 x 4.6 mm, Ea
00A-4251-E0

Luna 3 µm C18(2) 100 Å, LC Column 30 x 4.6 mm, Ea

View Product

  • 1. Acetophenone
  • 2. Benzene
  • 3. Toluene
  • 4. Naphthalene
-OEChem-06211003152D<br><br> 17 17  0     0  0  0  0  0  0999 V2000<br>    2.0000    1.7500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0420    1.2131    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    2.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4220    2.2869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  5  2  0  0  0  0<br>  2  3  2  0  0  0  0<br>  2  4  1  0  0  0  0<br>  2  5  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3 10  1  0  0  0  0<br>  4  7  2  0  0  0  0<br>  4 11  1  0  0  0  0<br>  5  9  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6 12  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 13  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>  9 15  1  0  0  0  0<br>  9 16  1  0  0  0  0<br>  9 17  1  0  0  0  0<br>M  END
Compound Name

Acetophenone

CID

7410

Molecular Formula

C8H8O

Molecular Weight

120

No. Hydrogen Bond Acceptors

1

Similar Applications

Application Specific

EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

20582

Application Specific

Fast EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea

20572

Reversed Phase

Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea

19812

Reversed Phase

Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea

19811

Reversed Phase

Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea

19810

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18803

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18802

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18801

High Temperature

EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT

Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

18785

Application Specific

Drug screen by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18175

Standard

EPA Method 8270C on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16584

EPA Method 8270C ZB-5MSi

16413

Application Specific

EPA Method 8270C on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16275

Improved Performance

Industrial Chemicals: Ketones on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

16238

Standard

Industrial Chemicals: Ketones on ZB-624

Zebron ZB-624, GC Cap. Column 30 m x 0.53 mm x 3.00 µm, Ea

16232

Standard

Common Drug Screen on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

16009

Common Drug Screen on ZB-1MS

16008

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea

15696

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15695

Standard

EPA Method 8270C on ZB-5MS 30x0.25x0.25

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14953

Standard

EPA Method 8270C on Guardian on ZB-5

Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14945