Antiulceratives on Polar-RP and Competitor Columns
LC Conditions
Column
Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea
Brand
Synergi
Part No
00F-4336-E0
Phase Name
Polar-RP
Elution Type
Isocratic
Mobile Phase
A: 20 mM Potassium phosphate pH 7.0
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
80
20
Flow Rate
1.00 mL/min
Temperature
25°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, POLAR-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-6076 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Famotidine
- 2. Cimetidine
- 3. Ranitidine
-OEChem-04281016552D<br><br> 35 35 0 0 0 0 0 0 0999 V2000<br> 7.7513 -0.0255 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4118 0.3857 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.7545 0.5654 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1028 1.3367 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7208 -0.5654 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3629 0.6947 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.2545 -0.9734 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8981 -0.9526 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.0146 -0.6947 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4608 0.0766 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 13.7088 -0.3346 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.5498 0.9526 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0571 0.3346 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8002 -0.3346 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4944 -0.6947 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1060 0.0255 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4455 -0.3857 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7545 0.5654 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.0635 -0.3857 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.7577 -0.0255 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5456 0.7163 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7660 0.8820 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3116 -0.7163 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0913 -0.8820 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0058 -1.0764 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7855 -1.2421 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.3901 1.0670 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3588 -1.3675 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3084 -1.1442 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.4915 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3318 -0.5298 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 14.1695 0.0803 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 13.8377 -0.9410 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 13.0105 1.3675 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.9601 1.1442 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 14 1 0 0 0 0<br> 1 15 1 0 0 0 0<br> 2 4 2 0 0 0 0<br> 2 5 2 0 0 0 0<br> 2 6 1 0 0 0 0<br> 2 10 1 0 0 0 0<br> 3 18 1 0 0 0 0<br> 3 19 1 0 0 0 0<br> 6 16 2 0 0 0 0<br> 7 17 1 0 0 0 0<br> 7 19 2 0 0 0 0<br> 8 16 1 0 0 0 0<br> 8 28 1 0 0 0 0<br> 8 29 1 0 0 0 0<br> 9 19 1 0 0 0 0<br> 9 20 2 0 0 0 0<br> 10 30 1 0 0 0 0<br> 10 31 1 0 0 0 0<br> 11 20 1 0 0 0 0<br> 11 32 1 0 0 0 0<br> 11 33 1 0 0 0 0<br> 12 20 1 0 0 0 0<br> 12 34 1 0 0 0 0<br> 12 35 1 0 0 0 0<br> 13 14 1 0 0 0 0<br> 13 16 1 0 0 0 0<br> 13 21 1 0 0 0 0<br> 13 22 1 0 0 0 0<br> 14 23 1 0 0 0 0<br> 14 24 1 0 0 0 0<br> 15 17 1 0 0 0 0<br> 15 25 1 0 0 0 0<br> 15 26 1 0 0 0 0<br> 17 18 2 0 0 0 0<br> 18 27 1 0 0 0 0<br>M END
Compound Name
Famotidine
CID
5702160
Molecular Formula
C8H15N7O2S3
Molecular Weight
337
No. Hydrogen Bond Acceptors
9
No. Hydrogen Bond Donors
4