Quinones

Quinones
LC Conditions
Column

Luna 3 µm C18(2) 100 Å, LC Column 75 x 4.6 mm, Ea

Brand

Luna

Part No

00C-4251-E0

Phase Name

C18(2)

Elution Type

Isocratic

Mobile Phase

A: Methanol

B: Water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

89

11

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 3 µm C18(2) 100 Å, LC Column 75 x 4.6 mm, Ea
00C-4251-E0

Luna 3 µm C18(2) 100 Å, LC Column 75 x 4.6 mm, Ea

View Product

  • 1. 1,4-Naphthoquinone
  • 2. Vitamin K3
  • 3. 9,10-Anthroquinone
  • 4. 1,5-Dichloro-9,10-anthraquinone
  • 5. 2-Methyl-9,10-anthroquinone
  • 6. 2-Ethyl-9,10-anthroquinone
  • 7. 2-tert-Butyl-9,10-anthroquinone
-OEChem-06211003152D<br><br> 18 19  0     0  0  0  0  0  0999 V2000<br>    2.8660   -2.0000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    2.0000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6260   -1.0347    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6260    1.0347    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5321   -0.5208    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5321    0.5208    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6188   -1.6546    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6188    1.6546    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -0.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0678   -0.8329    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0678    0.8329    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  5  2  0  0  0  0<br>  2  6  2  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  7  2  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4  8  2  0  0  0  0<br>  5  9  1  0  0  0  0<br>  6 10  1  0  0  0  0<br>  7 11  1  0  0  0  0<br>  7 13  1  0  0  0  0<br>  8 12  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>  9 10  2  0  0  0  0<br>  9 15  1  0  0  0  0<br> 10 16  1  0  0  0  0<br> 11 12  2  0  0  0  0<br> 11 17  1  0  0  0  0<br> 12 18  1  0  0  0  0<br>M  END
Compound Name

1,4-Naphthoquinone

CID

8530

Molecular Formula

C10H6O2

Molecular Weight

158

No. Hydrogen Bond Acceptors

2

Similar Applications

Application Specific

EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

20582

Application Specific

Fast EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea

20572

Standard

EPA Method 8270C on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16584

EPA Method 8270C ZB-5MSi

16413

Application Specific

EPA Method 8270C on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16275

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea

15696

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15695

Standard

EPA Method 8270C on ZB-5MS 30x0.25x0.25

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14953

Standard

EPA Method 8270C on Guardian on ZB-5

Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14945