Cholorobenzenes on Luna 5u Phenyl-Hexyl

Cholorobenzenes on Luna 5u Phenyl-Hexyl
LC Conditions
Column

Luna 5 um Phenyl-Hexyl 100 A,LC Column 150 x 4.6 mm,Ea

Brand

Luna

Part No

00F-4257-E0

Phase Name

Phenyl-Hexyl

Elution Type

Gradient

Mobile Phase

A: Water

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

10

60

40

2

10

45

55

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Phenyl 4 x 3.0mm, 10/Pk Part No.: AJ0-4351 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, ea
00F-4257-E0

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, ea

View Product

  • 1. Chlorobenzene
  • 2. 1,2-Dichlorobenzene
  • 3. 1.4-Dichlorobenzene
  • 4. 1,2,3-Trichlorobenzene
  • 5. 1,3,5-Trichlorobenzene
  • 6. 1,2,3,4-Tetrachlorobenzene
-OEChem-06211003152D<br><br> 12 12  0     0  0  0  0  0  0999 V2000<br>    2.8660    1.5000    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  2  1  0  0  0  0<br>  2  3  2  0  0  0  0<br>  2  4  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  8  1  0  0  0  0<br>  4  6  2  0  0  0  0<br>  4  9  1  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5 10  1  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6 11  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>M  END
Compound Name

Chlorobenzene

CID

7964

Molecular Formula

C6H5Cl

Molecular Weight

112

Similar Applications

Application Specific

EPA 505.1 by GC/ECD on ZB-CLPesticides-2 (Hydrogen Gas)

Zebron ZB-CLPesticides-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

23637

Application Specific

EPA 505.1 by GC/ECD on ZB-CLPesticides-1 (Hydrogen Gas)

Zebron ZB-CLPesticides-1, GC Cap. Column 30 m x 0.32 mm x 0.32 µm, Ea

23636

Application Specific

EPA 508.1 on ZB-CLPesticides-2 (Hydrogen gas)

Zebron ZB-CLPesticides-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

23626

Application Specific

EPA 508.1 on ZB-CLPesticides-1 (Hydrogen gas)

Zebron ZB-CLPesticides-1, GC Cap. Column 30 m x 0.32 mm x 0.32 µm, Ea

23625

Application Specific

EPA 508 by GC/ECD on ZB-CLPesticides-2 (Helium Gas)

Zebron ZB-CLPesticides-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

22636

Application Specific

EPA 508 by GC/ECD on ZB-CLPesticides-1 (Helium Gas)

Zebron ZB-CLPesticides-1, GC Cap. Column 30 m x 0.32 mm x 0.32 µm, Ea

22635

Application Specific

EPA 505.1 by GC/ECD on ZB-CLPesticides-2 (Helium Gas)

Zebron ZB-CLPesticides-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

22622

Application Specific

EPA 505.1 by GC/ECD on ZB-CLPesticides-1 (Helium Gas)

Zebron ZB-CLPesticides-1, GC Cap. Column 30 m x 0.32 mm x 0.32 µm, Ea

22621

Application Specific

Chlorinated Pesticides - 8081B on ZB-MR-2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

22057

Application Specific

Chlorinated Pesticides - 8081B on ZB-MR-1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

22056

Application Specific

Chlorinated Pesticides (508 list) on ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

21439

Application Specific

EPA Method 525.2 on ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

21438

Application Specific

EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

20582

Application Specific

Fast EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea

20572

High Temperature

EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT

Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

18785

High Temperature

EPA Methods 508 and 8081A by ECD on ZB-35HT

Zebron ZB-35HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

18768

High Temperature

EPA Methods 508 and 8081A by MSD on ZB-35HT

Zebron ZB-35HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

18199

Application Specific

Organochloropesticides (OCP) and Polychlorinated Biphenyls (PCB) in Milk and Milk Products by GC/ECD

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

17910

Application Specific

Organochloropesticides (OCP) and Polychlorinated Biphenyls (PCB) in Milk and Milk Products by GC/ECD

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

17909

Application Specific

Chlorinated Pesticides (EPA 508) Mix # 2 on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

17582

Standard

EPA Method 8270C on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16584

EPA Method 8270C ZB-5MSi

16413

EPA 8081A Additional Compounds on ZB-5MSi

16412

Improved Performance

USP 467 Procedure B - Class 2 Mix A by GC/FID on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16353

Standard

USP 467 Procedure A - Class 2 Mix A by GC/FID on ZB-624

Zebron ZB-624, GC Cap. Column 30 m x 0.32 mm x 1.80 µm, Ea

16349

Application Specific

EPA Methods 508 and 8081A on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16280

Application Specific

EPA Methods 508 and 8081A on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16279

Application Specific

EPA Method 8270C on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16275

Application Specific

Organochlorine Pesticides in Water by GC/ECD

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16241

Application Specific

Expanded Chlorinated Pesticides on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16240

Standard

Halocarbons on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.32 mm x 1.00 µm, Ea

16228

Application Specific

EPA 8081: Organochlorine Pesticides on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16226

Application Specific

EPA 8081: Organochlorine Pesticides on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16225

EPA Method 8081: Connecticut and Massachusetts State Specific Methods on ZB-MR2

16189

Application Specific

EPA Method 8081: Connecticut and Massachusetts State Specific Methods on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.53 mm x 0.50 µm, Ea

16188

Standard

EPA 505 - Organohalide Pesticides on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.32 mm x 1.00 µm, Ea

16069

Improved Performance

Solvents on ZB-WAXplus 30x0.25x0.25

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15926

Standard

EPA Method 8260 - Volatile Organic Analysis on Zebron ZB-624 20m x 0.18mm x 1.00um

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

15866

Standard

EPA Method 8260B: Volatile Organic Analysis on ZB-624

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

15697

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea

15696

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15695

Organochlorine Pesticides: EPA Method 8081A on ZB1ms 30x0.25x0.25

15575

Standard

EPA Method 8270C on ZB-5MS 30x0.25x0.25

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14953

Standard

EPA Method 8270 Base Mix on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14949

Standard

EPA Method 8270 Acids Mix on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14948

Standard

EPA Method 8270C on Guardian on ZB-5

Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14945

Standard

Chlorinated Hydrocarbons: EPA Method 612 - ZB-5 30x0.53x0.5

Zebron ZB-5, GC Cap. Column 30 m x 0.53 mm x 0.50 µm, Ea

14879

Standard

Industrial Solvents on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

14809

Standard

Industrial Solvents on ZB-WAX 30x0.25x0.25

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14808

Standard

Industrial Solvents on ZB-624 60x0.32x1.8

Zebron ZB-624, GC Cap. Column 60 m x 0.32 mm x 1.80 µm, Ea

14807

Standard

EPA Method 8260: Volatile Organics on ZB-624

Zebron ZB-624, GC Cap. Column 60 m x 0.25 mm x 1.40 µm, Ea

14783

Standard

EPA Method 525.2: Organic compounds in Drinking Water on ZB-5 on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14771

Standard

8270 Semi-Volatile Organic Analysis on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14567

Standard

Semivolatiles (BNA) by GC/MS (EPA Method 8270C)

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea

14442

Standard

Volatile Organics by GC/MS (EPA Method 8260B)

Zebron ZB-624, GC Cap. Column 60 m x 0.53 mm x 3.00 µm, Ea

14441

Standard

EPA Method 505 - Organohalide Pesticide Mix

Zebron ZB-1, GC Cap. Column 30 m x 0.32 mm x 1.00 µm, Ea

14324

Standard

EPA Method 624 CLP

Zebron ZB-624, GC Cap. Column 30 m x 0.53 mm x 3.00 µm, Ea

14323

Standard

EPA Method 624 Calibration Mix

Zebron ZB-624, GC Cap. Column 60 m x 0.25 mm x 1.40 µm, Ea

5148

Standard

Aromatic Analysis

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

1307

Standard

Volatile Organic Compounds

Zebron ZB-624, GC Cap. Column 30 m x 0.25 mm x 1.40 µm, Ea

1306