Benzodiazepines
LC Conditions
Column
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4257-E0
Phase Name
Phenyl-Hexyl
Elution Type
Isocratic
Mobile Phase
A: Methanol
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
80
20
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Phenyl 4 x 3.0mm, 10/Pk Part No.: AJ0-4351 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Lormetazepam
- 2. Diazepam
- 3. Oxazepam
-OEChem-06211003152D<br><br> 34 36 0 1 0 0 0 0 0999 V2000<br> 8.1647 0.0492 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6300 0.7381 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -0.9749 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1204 -2.6577 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7188 -2.0984 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7439 -0.0740 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5006 -0.4749 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5006 -1.4749 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7188 0.1486 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3100 -0.9749 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7439 -1.8759 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9413 1.1235 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3946 0.0597 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3946 -2.0096 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9413 -3.0734 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3006 -0.4541 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3006 -1.4957 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8969 1.4182 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2083 1.8037 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1194 2.3932 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4308 2.7786 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3864 3.0734 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9801 -0.4500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3874 0.6797 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3874 -2.6296 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3369 -3.2113 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0793 -3.6778 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5458 -2.9354 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8364 -1.8078 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6158 1.6209 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7119 2.5759 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9763 3.2003 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.4380 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5243 3.6778 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 16 1 0 0 0 0<br> 2 18 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 3 33 1 0 0 0 0<br> 4 11 2 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 11 1 0 0 0 0<br> 5 15 1 0 0 0 0<br> 6 9 2 0 0 0 0<br> 6 10 1 0 0 0 0<br> 7 8 2 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 13 1 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 12 1 0 0 0 0<br> 10 11 1 0 0 0 0<br> 10 23 1 0 0 0 0<br> 12 18 1 0 0 0 0<br> 12 19 2 0 0 0 0<br> 13 16 2 0 0 0 0<br> 13 24 1 0 0 0 0<br> 14 17 2 0 0 0 0<br> 14 25 1 0 0 0 0<br> 15 26 1 0 0 0 0<br> 15 27 1 0 0 0 0<br> 15 28 1 0 0 0 0<br> 16 17 1 0 0 0 0<br> 17 29 1 0 0 0 0<br> 18 20 2 0 0 0 0<br> 19 21 1 0 0 0 0<br> 19 30 1 0 0 0 0<br> 20 22 1 0 0 0 0<br> 20 31 1 0 0 0 0<br> 21 22 2 0 0 0 0<br> 21 32 1 0 0 0 0<br> 22 34 1 0 0 0 0<br>M END
Compound Name
Lormetazepam
CID
13314
Molecular Formula
C16H12Cl2N2O2
Molecular Weight
335
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Similar Applications
Standard
Benzodiazepines by MSD on a ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16557
Reversed Phase
Benzodiazepines
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, Ea
1243