Diazepams
LC Conditions
Column
Synergi 4 µm Max-RP 80 Å, LC Column 30 x 2 mm, Ea
Brand
Synergi
Part No
00A-4337-B0
Phase Name
Max-RP
Elution Type
Gradient
Mobile Phase
A: Water with 0.1% TFA
B: Acetonitrile with 0.1% TFA
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
95
5
2
3
5
95
Flow Rate
1.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C12 4 x 2.0mm, 10/Pk Part No.: AJ0-6073 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Oxazepam
- 2. Temazepam
- 3. Nordiazepam
- 4. Diazepam
-OEChem-06211003152D<br><br> 31 33 0 1 0 0 0 0 0999 V2000<br> 8.1647 -0.1360 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -1.1602 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1204 -2.8430 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7188 -2.2836 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7439 -0.2592 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5006 -0.6602 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7188 -0.0367 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5006 -1.6602 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9413 0.9383 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3100 -1.1602 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.3946 -0.1255 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3946 -2.1948 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7439 -2.0611 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3006 -0.6393 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3006 -1.6810 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8969 1.2330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2083 1.6184 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1194 2.2079 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4308 2.5934 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3864 2.8881 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9801 -0.6352 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8568 -2.8881 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3874 0.4945 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3874 -2.8148 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8364 -1.9930 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3514 0.8113 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6158 1.4357 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7119 2.3907 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9763 3.0151 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5243 3.4926 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.6232 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 14 1 0 0 0 0<br> 2 10 1 0 0 0 0<br> 2 31 1 0 0 0 0<br> 3 13 2 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 22 1 0 0 0 0<br> 5 7 2 0 0 0 0<br> 5 10 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 11 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 8 12 1 0 0 0 0<br> 9 16 2 0 0 0 0<br> 9 17 1 0 0 0 0<br> 10 13 1 0 0 0 0<br> 10 21 1 0 0 0 0<br> 11 14 2 0 0 0 0<br> 11 23 1 0 0 0 0<br> 12 15 2 0 0 0 0<br> 12 24 1 0 0 0 0<br> 14 15 1 0 0 0 0<br> 15 25 1 0 0 0 0<br> 16 18 1 0 0 0 0<br> 16 26 1 0 0 0 0<br> 17 19 2 0 0 0 0<br> 17 27 1 0 0 0 0<br> 18 20 2 0 0 0 0<br> 18 28 1 0 0 0 0<br> 19 20 1 0 0 0 0<br> 19 29 1 0 0 0 0<br> 20 30 1 0 0 0 0<br>M END
Compound Name
Oxazepam
CID
4616
Molecular Formula
C15H11ClN2O2
Molecular Weight
286
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
2
Similar Applications
Reversed Phase
Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS
Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea
25864
Benzodiazepines extracted using Strata Screen C 150mg/3cc from Blood (TIC)
23894
Benzodiazepines extracted using Strata Screen C 150mg/3cc from Urine (TIC)
23893
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm
Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
23445
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23444
Reversed Phase
Drugs of Abuse by LCMS using Luna Omega 1.6u C18 50x2.1mm
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
23443
Chiral
Oxazepram on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23341
Chiral
Oxazepam on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23324
Chiral
Oxazepam on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23306
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22122
Reversed Phase
Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22121
Reversed Phase
Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm
Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22120
Reversed Phase
Pain Panel Benzodiazapines using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22109
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22104
Chiral
Oxazepam on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21288
Chiral
Oxazepam on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21287
Chiral
Oxazepam on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21286
Chiral
Oxazepam on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21285
Chiral
Oxazepam on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21284
Chiral
Oxazepam on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21283
Reversed Phase
Pain Panel using Strata-X-Drug B and Kinetex Phenyl-Hexyl 2.6u 50x4.6mm
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea
20847
Reversed Phase
Pain Panel/Drug Screening by LCMS using Kinetex 2.6u C18 50x3.0mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 3 mm, Ea
20689
Reversed Phase
Pain Panel Mix-41 in Human Urine on Luna 3u, PFP(2), 50x3 by LC-MS/MS
Luna 3 µm PFP(2) 100 Å, LC Column 50 x 3 mm, Ea
20594
Chiral
Oxazepam on Lux 5µm Cellulose-1 in PO
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20283
Chiral
Oxazepam on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20232
Reversed Phase
Separation of Benzodiazepines
Synergi 4 µm Hydro-RP 80 Å, LC Column 50 x 2 mm, Ea
20047
Reversed Phase
Benzodiazepines using Kinetex 2.6u C18 50x2.1mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19906
Reversed Phase
Benzodiazepines using Kinetex 2.6u Phenyl-Hexyl 50x2.1mm
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2.1 mm, Ea
19904
Reversed Phase
Benzodiazepines from urine using Strata-X-Drug N on a Kinetex C18 2.6µm, 50x2.1mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19714
Reversed Phase
Extraction of Benzodiazepines Using Strata Screen-C on Kinetex 2.6µm C18 50 x 2.1mm ID by LCMS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18849
Application Specific
Benzodiazepines(with extra internal standards) by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18779
Oxazepam Lux 5 µm Amylose-2 250 x 4.6mm in PO-95%CH3CN
18142
Chiral
Oxazepam on Lux 5 µm Cellulose-1 250 x 4.6mm ID in PO-95%CH3CN
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18141
Application Specific
Benzodiazepines from urine by Screen C on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18055
Benzodiazepines by MSD on a ZB-5MSi
17894
Standard
Benzodiazepines by MSD on a ZB-5MS
Zebron ZB-5MS, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
17893
Application Specific
Benzodiazepines by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
17808
Chiral
Oxazapam on Lux 5µ Cellulose-2 250 x 4.6mm in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17671
Chiral
Oxazapam on Lux 5µ Cellulose-1 250 x 4.6mm in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17663
Benzodiazepines by MSD on a ZB-1MS
17620
Benzodiazepines by MSD on a ZB-XLB
17619
Extraction of Diazepams from Urine on ZB-1MS
16744
Standard
Benzodiazepines by MSD on a ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16557
Reversed Phase
MercuryMS - Luna 3µm C18(2) 20 x 2.0mm for Benzodiazepines in Plasma by LC/MS/MS
Luna 3 µm C18(2) 100 Å, LC Column 20 x 2 mm, MercuryMS, Ea
16040
Benzodiazepines on ZB-1MS
15782
Reversed Phase
Benzodiazepines on Synergi 2.5µm Max-RP 20 x 2.0mm Mini-Column
Synergi 2.5 µm Max-RP 100 Å, LC Column 20 x 2 mm, MercuryMS, Ea
15463
Reversed Phase
Benzodiazepines Standards on Gemini C18
Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea
15456
Reversed Phase
Benzodiazepines (SPE-Plasma) on Hybrid C18 Column
Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea
15454
Reversed Phase
Benzodiazepines
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, Ea
1243