Pesticides/Herbicides
LC Conditions
Column
Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4255-E0
Phase Name
CN
Elution Type
Isocratic
Gradient Profile
Step No.
Time(min)
%A
%B
2
5
65
35
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, CN 4 x 3.0mm, 10/Pk Part No.: AJ0-4305 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Tebuthiuron
- 2. Carbofuran
- 3. Carbaryl
- 4. Diuron
- 5. Captan
- 6. Barban
-OEChem-06211003152D<br><br> 31 31 0 0 0 0 0 0 0999 V2000<br> 6.1974 -0.6133 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9021 1.3127 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6974 0.9255 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4374 -0.3346 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6974 0.9255 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7431 0.0255 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9575 -0.3346 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0064 -0.0255 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9086 -0.6436 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.2665 0.6165 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6485 -1.2856 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3884 -0.0255 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2294 -1.3127 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6942 0.3346 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.6947 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7170 -1.2332 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4982 -0.8352 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.1001 -0.0539 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.8562 0.4249 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4581 1.2062 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6769 0.8081 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0588 -1.0940 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4569 -1.8753 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.2381 -1.4772 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6230 -1.1838 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1005 -1.9192 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8359 -1.4416 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6142 -0.5809 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4149 1.1554 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.5392 1.1095 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.5851 0.2339 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 8 1 0 0 0 0<br> 1 12 1 0 0 0 0<br> 2 14 2 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 8 2 0 0 0 0<br> 4 12 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 14 1 0 0 0 0<br> 5 12 2 0 0 0 0<br> 6 14 1 0 0 0 0<br> 6 15 1 0 0 0 0<br> 6 28 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 9 16 1 0 0 0 0<br> 9 17 1 0 0 0 0<br> 9 18 1 0 0 0 0<br> 10 19 1 0 0 0 0<br> 10 20 1 0 0 0 0<br> 10 21 1 0 0 0 0<br> 11 22 1 0 0 0 0<br> 11 23 1 0 0 0 0<br> 11 24 1 0 0 0 0<br> 13 25 1 0 0 0 0<br> 13 26 1 0 0 0 0<br> 13 27 1 0 0 0 0<br> 15 29 1 0 0 0 0<br> 15 30 1 0 0 0 0<br> 15 31 1 0 0 0 0<br>M END
Compound Name
Tebuthiuron
CID
5383
Molecular Formula
C9H16N4OS
Molecular Weight
228
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Pesticide panel using Kinetex 2.6u Polar C18 50x4.6mm
Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24017
Reversed Phase
185 Pesticides on Kinetex Biphenyl 5u
Kinetex 5 µm Biphenyl 100 Å, LC Column 100 x 2.1 mm, Ea
22618
Reversed Phase
Quantification of Phenylurea Pesticides by QuEchERS and LC/MS/MS
Synergi 2.5 µm Fusion-RP 100 Å, LC Column 50 x 2 mm, Ea
20894
Normal Phase
Pesticides/Herbicides
Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea
12923