Carbamate/Urea Pesticides
LC Conditions
Column
Luna 3 µm CN 100 Å, LC Column 100 x 4.6 mm, Ea
Brand
Luna
Part No
00D-4254-E0
Phase Name
CN
Elution Type
Gradient
Mobile Phase
A: Hexane
B: 80:20 Methylene chloride:Methanol
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
95
5
2
2
85
15
Flow Rate
5.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, CN 4 x 3.0mm, 10/Pk Part No.: AJ0-4305 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Carbofuran
- 2. Barban
- 3. Carbaryl
- 4. Tebuthiuron
- 5. Diuron
-OEChem-06211003142D<br><br> 31 32 0 0 0 0 0 0 0999 V2000<br> 5.5443 -0.6953 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.0000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1279 -1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5443 -2.3047 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9369 -2.0878 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9369 -0.9122 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2933 -2.8716 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0817 -2.6140 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5725 -2.5894 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4385 -2.4522 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3014 -1.5862 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3014 -1.4138 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4385 -0.5478 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5725 -0.4106 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -0.6900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 3.0369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 1.9631 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 5 1 0 0 0 0<br> 1 8 1 0 0 0 0<br> 2 12 1 0 0 0 0<br> 2 15 1 0 0 0 0<br> 3 15 2 0 0 0 0<br> 4 15 1 0 0 0 0<br> 4 16 1 0 0 0 0<br> 4 28 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 10 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 17 1 0 0 0 0<br> 6 18 1 0 0 0 0<br> 7 8 2 0 0 0 0<br> 7 11 1 0 0 0 0<br> 8 12 1 0 0 0 0<br> 9 19 1 0 0 0 0<br> 9 20 1 0 0 0 0<br> 9 21 1 0 0 0 0<br> 10 22 1 0 0 0 0<br> 10 23 1 0 0 0 0<br> 10 24 1 0 0 0 0<br> 11 13 2 0 0 0 0<br> 11 25 1 0 0 0 0<br> 12 14 2 0 0 0 0<br> 13 14 1 0 0 0 0<br> 13 26 1 0 0 0 0<br> 14 27 1 0 0 0 0<br> 16 29 1 0 0 0 0<br> 16 30 1 0 0 0 0<br> 16 31 1 0 0 0 0<br>M END
Compound Name
Carbofuran
CID
2566
Molecular Formula
C12H15NO3
Molecular Weight
221
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Cannabis pesticide screening using Kinetex 2.6um Polar C18 50x4.6mm
Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24145
Reversed Phase
Cannabis pesticide screening using Luna Omega 3um Polar C18 50x4.6mm
Luna Omega 3 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24144
Reversed Phase
Pesticide panel using Kinetex 2.6u Polar C18 50x4.6mm
Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24017
Reversed Phase
185 Pesticides on Kinetex Biphenyl 5u
Kinetex 5 µm Biphenyl 100 Å, LC Column 100 x 2.1 mm, Ea
22618
Reversed Phase
Carbamate pesticides on Kinetex C18, 5u with LC/MS/MS detection
Kinetex 5 µm C18 100 Å, LC Column 150 x 2.1 mm, Ea
22064
Reversed Phase
Screening >350 Pesticides from Food & Feed According to Regulation (EC) No. 396/2005
Synergi 2.5 µm Fusion-RP 100 Å, LC Column 50 x 2 mm, Ea
20924
Reversed Phase
Quantification of Carbamates Fungicides in Beverage by LC/MS/MS
Gemini 3 µm C18 110 Å, LC Column 50 x 2 mm, Ea
20025
Reversed Phase
Quantification of Carbamate Pesticides by QuEchERS and LC/MS/MS
Synergi 4 µm Fusion-RP 80 Å, LC Column 50 x 2 mm, Ea
20018
Reversed Phase
Carbamate Pesticide with and without sample focusing on Kinetex C18 2.6µm 50x2.1mm by LCMS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19168
Reversed Phase
EPA Method 8318, N-Methylcarbamates
Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea
14496
Reversed Phase
EPA Method 632, Carbamate and Urea Pesticides
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
14483
Reversed Phase
EPA Method 531.1 - n-Methylcarbamoyloximes & n-Methylcarbamates
Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea
14470
Normal Phase
Pesticides/Herbicides
Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea
12923
Carbamate/Urea Pesticides on Envirosep-PP (EPA Method 632)
5301