Ephedrine
LC Conditions
Column
Chirex (S)-ICA and (R)-NEA, LC Column 250 x 4.6 mm, Ea
Brand
Chirex
Part No
00G-3022-E0
Phase Name
No Phase
Elution Type
Isocratic
Mobile Phase
A: Hexane/Dichloroethane/Ethanol-TFA 55:35:10
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Ephedrine
- 2. Ephedrine
-OEChem-06211003152D<br><br> 27 27 0 1 0 0 0 0 0999 V2000<br> 2.0000 1.0000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.0000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.0000 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.8660 0.5000 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4682 1.4250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.3500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2881 -0.0369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 0.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9081 1.0369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.6900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -0.6900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9081 1.9631 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2881 3.0369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -3.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 4 1 0 0 0 0<br> 1 21 1 0 0 0 0<br> 2 3 1 0 0 0 0<br> 2 9 1 0 0 0 0<br> 2 18 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 13 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 14 1 0 0 0 0<br> 5 7 2 0 0 0 0<br> 5 8 1 0 0 0 0<br> 6 15 1 0 0 0 0<br> 6 16 1 0 0 0 0<br> 6 17 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 7 19 1 0 0 0 0<br> 8 11 2 0 0 0 0<br> 8 20 1 0 0 0 0<br> 9 22 1 0 0 0 0<br> 9 23 1 0 0 0 0<br> 9 24 1 0 0 0 0<br> 10 12 2 0 0 0 0<br> 10 25 1 0 0 0 0<br> 11 12 1 0 0 0 0<br> 11 26 1 0 0 0 0<br> 12 27 1 0 0 0 0<br>M END
Compound Name
Ephedrine
CID
5032
Molecular Formula
C10H15NO
Molecular Weight
165
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Chiral Amphetamines with Ephedrines & Pseudoephedrines on Lux 3µm AMP 150x3mm
Lux 3 µm AMP, LC Column 150 x 3.0 mm, EA
23640
Chiral
Norephedrine on LUX Amylose-1 5u 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23191
Reversed Phase
Antihistamines on Kinetex 2.6u F5 50x4.6mm at pH 2.9 and pH 7.2
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
22838
Reversed Phase
Antihistamines using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22716
Chiral
Ephedrine on Lux 5µm Cellulose-2 by SFC
Lux 5 um Cellulose-2,LC Column 250 x 4.6 mm,Ea
21116
Chiral
Ephedrine on Lux 5µm Cellulose-2 by SFC
Lux 5 um Cellulose-2,LC Column 250 x 4.6 mm,Ea
21115
Chiral
Ephedrine on Lux 5µm Cellulose-1 by SFC
Lux 5 um Cellulose-1,LC Column 250 x 4.6 mm,Ea
21114
Reversed Phase
Extraction of Amphetamines-NIDA5 Using Strata X-C on Kinetex 2.6µm C18 50 x 2.1mm by LCMS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18845
Application Specific
Alternative amphetamines by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18490
Application Specific
Expanded amphetamines and interferences including TFMPP by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18039
Expanded Amphetamines and Interferences by MSD on a ZB-5MSi
17933
Application Specific
Expanded Amphetamines and Interferences by MSD on a ZB-Drug-1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
17932
Reversed Phase
Extraction of Amphetamines on Strata-X-C
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
17192
Reversed Phase
Drug mixture extracted from Plasma using PPT
Onyx Monolithic C18, LC Column 100 x 4.6 mm, Ea
15587
Reversed Phase
Catecholamines on Onyx C18
Onyx Monolithic C18, LC Column 100 x 4.6 mm, Ea
15480
Standard
Drugs of Abuse
Zebron ZB-1, GC Cap. Column 15 m x 0.53 mm x 0.50 µm, Ea
1080