Epinephrine

Epinephrine
LC Conditions
Column

Chirex (S)-LEU and (R)-NEA, LC Column 250 x 4.6 mm, Ea

Brand

Chirex

Part No

00G-3020-E0

Phase Name

3020 (S)-tert-leucine and (R)-1-(alpha-naphthyl)ethylamine

Elution Type

Isocratic

Mobile Phase

A: Hexane/Dichloroethane/Ethanol-TFA (55:35:10) ethanol-TFA 20:1

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info

Order Items Used in This Application

Chirex (S)-LEU and (R)-NEA, LC Column 250 x 4.6 mm, Ea
00G-3020-E0

Chirex (S)-LEU and (R)-NEA, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Epinephrine
  • 2. Epinephrine
-OEChem-06211003152D<br><br> 26 26  0     1  0  0  0  0  0999 V2000<br>    3.4030    1.6550    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5369   -1.8450    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -2.8450    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    2.6550    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    1.1550    0.0000 C   0  0  2  0  0  0  0  0  0  0  0  0<br>    4.2690    0.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    1.6550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -0.3450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -0.3450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -1.3450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -1.3450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.8450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010    3.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    1.7750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3471    1.0724    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7456    1.7627    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.0350    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6720   -0.0350    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    2.9650    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6720   -1.6550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030    2.2750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3110    2.6181    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5380    3.4650    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6910    3.6919    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.5350    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8059   -3.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  5  1  1  1  0  0  0<br>  1 21  1  0  0  0  0<br>  2 10  1  0  0  0  0<br>  2 25  1  0  0  0  0<br>  3 12  1  0  0  0  0<br>  3 26  1  0  0  0  0<br>  4  7  1  0  0  0  0<br>  4 13  1  0  0  0  0<br>  4 19  1  0  0  0  0<br>  5  6  1  0  0  0  0<br>  5  7  1  0  0  0  0<br>  5 14  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6  9  1  0  0  0  0<br>  7 15  1  0  0  0  0<br>  7 16  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 17  1  0  0  0  0<br>  9 11  2  0  0  0  0<br>  9 18  1  0  0  0  0<br> 10 12  2  0  0  0  0<br> 11 12  1  0  0  0  0<br> 11 20  1  0  0  0  0<br> 13 22  1  0  0  0  0<br> 13 23  1  0  0  0  0<br> 13 24  1  0  0  0  0<br>M  END
Compound Name

Epinephrine

CID

5816

Molecular Formula

C9H13NO3

Molecular Weight

183

No. Hydrogen Bond Acceptors

4

No. Hydrogen Bond Donors

4

Similar Applications

Reversed Phase

Kinetex PS C18 100 % Aqueous Stability Test

Kinetex 2.6 µm PS C18 100 Å, LC Column 50 x 4.6 mm, Ea

25564

Chiral

Epinephrine on Lux 5µ Amylose-1 250x4.6mm

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

24278

Reversed Phase

pMETS in plasma using Luna Omega Polar C18 100x2.1mm

Luna Omega 1.6µm Polar C18 100Å, LC Column 100 x 2.1 mm, EA

23592

Reversed Phase

Catecholamines using Luna Omega Polar C18 100x2.1mm

Luna Omega 1.6µm Polar C18 100Å, LC Column 100 x 2.1 mm, EA

23591

Reversed Phase

100% Aqueous Stability - Kinetex 5u EVO C18 50x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 50 x 4.6 mm, Ea

22778

Hydrophilic Interaction

Catecholamines on Kinetex 2.6 µm HILIC 50 x 4.6 mm Agilent 1200

Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea

18890

Reversed Phase

Catecholamines on Kinetex 2.6µm C18 150 x 4.6mm ID ( in ammonium formate buffer)

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

18704

Reversed Phase

Catecholamines on Kinetex 2.6µm C18 150 x 4.6mm ID

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

18687

Reversed Phase

Catecholamines using Synergi Fusion-RP

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea

15738

Reversed Phase

Catecholamines in 100% Aqueous by Gemini 5um C18

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

15613

Catecholamines on Onyx C18

15480

Reversed Phase

Polar Bases -- Catecholamines

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

15025

Reversed Phase

Catecholamines on Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea

14217