Arginine

Arginine
LC Conditions
Column

Chirex 3126 (D)-penicillamine, LC Column 150 x 4.6 mm, Ea

Brand

Chirex

Part No

00F-3126-E0

Phase Name

3126 (D)-penicillamine

Elution Type

Isocratic

Mobile Phase

A: 1 mM Copper (II) sulfate in water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info

Order Items Used in This Application

Chirex 3126 (D)-penicillamine, LC Column 150 x 4.6 mm, Ea
00F-3126-E0

Chirex 3126 (D)-penicillamine, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. L-Arginine
  • 2. D-Arginine
-OEChem-06211003152D<br><br> 26 25  0     1  0  0  0  0  0999 V2000<br>    6.8671    1.8100    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010    3.3100    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    2.3100    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -1.1900    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5369   -2.6900    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -2.6900    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    0.8100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.3100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    1.8100    0.0000 C   0  0  1  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.6900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010    2.3100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -2.1900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3471    0.2274    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7456    0.9177    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0569    0.8926    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.6584    0.2023    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    2.4300    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4810   -1.2726    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8796   -0.5823    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.0000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    2.9300    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.4040    2.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5369   -3.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.3800    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -3.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8059   -2.3800    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 11  1  0  0  0  0<br>  1 22  1  0  0  0  0<br>  2 11  2  0  0  0  0<br>  9  3  1  6  0  0  0<br>  3 20  1  0  0  0  0<br>  3 21  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  4 12  2  0  0  0  0<br>  5 12  1  0  0  0  0<br>  5 23  1  0  0  0  0<br>  5 24  1  0  0  0  0<br>  6 12  1  0  0  0  0<br>  6 25  1  0  0  0  0<br>  6 26  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 13  1  0  0  0  0<br>  7 14  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 15  1  0  0  0  0<br>  8 16  1  0  0  0  0<br>  9 11  1  0  0  0  0<br>  9 17  1  0  0  0  0<br> 10 18  1  0  0  0  0<br> 10 19  1  0  0  0  0<br>M  END
Compound Name

L-Arginine

CID

6322

Molecular Formula

C6H14N4O2

Molecular Weight

174

No. Hydrogen Bond Acceptors

6

No. Hydrogen Bond Donors

4

Similar Applications

HILIC

LC-MS/MS Separation of Amino Acid Isomers- Sarcosine, beta-Alanine, and L-Alanine- clone

bioZen 2.6 µm Glycan, LC Column 100 x 2.1 mm, Ea

25781

HILIC

LC-MS/MS Separation of Amino Acid Isomers- Leucine and Iso-Leucine

bioZen 2.6 µm Glycan, LC Column 100 x 2.1 mm, Ea

25780