Diazepam and related compounds on Synergi Polar-RP in Methanol
LC Conditions
Column
Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea
Brand
Synergi
Part No
00F-4336-E0
Phase Name
Polar-RP
Elution Type
Isocratic
Mobile Phase
A: Methanol
B: 20mM Potassium phosphate pH 2.5
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
70
30
Flow Rate
1.50 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, POLAR-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-6076 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Clonazepam
- 2. Desmethyldiazepam
- 3. Temazepam
- 4. Diazepam
-OEChem-06211003152D<br><br> 32 34 0 0 0 0 0 0 0999 V2000<br> 5.5096 0.5528 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.8430 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9123 -0.6327 0.0000 O 0 5 0 0 0 0 0 0 0 0 0 0<br> 7.0405 0.8640 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5984 -2.2836 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6235 -0.2592 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0444 -0.1360 0.0000 N 0 3 0 0 0 0 0 0 0 0 0 0<br> 4.3802 -0.6602 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3802 -1.6602 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5984 -0.0367 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8209 0.9383 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2742 -0.1255 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2742 -2.1948 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.1896 -1.1602 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1803 -0.6393 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6235 -2.0611 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1803 -1.6810 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7765 1.2330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.0879 1.6184 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9990 2.2079 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3104 2.5934 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2660 2.8881 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2670 0.4945 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7364 -2.8881 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2670 -2.8148 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7049 -0.7736 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7049 -1.5467 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7160 -1.9930 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4954 1.4357 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5915 2.3907 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8559 3.0151 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4039 3.4926 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 18 1 0 0 0 0<br> 2 16 2 0 0 0 0<br> 3 7 1 0 0 0 0<br> 4 7 2 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 16 1 0 0 0 0<br> 5 24 1 0 0 0 0<br> 6 10 2 0 0 0 0<br> 6 14 1 0 0 0 0<br> 7 15 1 0 0 0 0<br> 8 9 2 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 12 1 0 0 0 0<br> 9 13 1 0 0 0 0<br> 10 11 1 0 0 0 0<br> 11 18 1 0 0 0 0<br> 11 19 2 0 0 0 0<br> 12 15 2 0 0 0 0<br> 12 23 1 0 0 0 0<br> 13 17 2 0 0 0 0<br> 13 25 1 0 0 0 0<br> 14 16 1 0 0 0 0<br> 14 26 1 0 0 0 0<br> 14 27 1 0 0 0 0<br> 15 17 1 0 0 0 0<br> 17 28 1 0 0 0 0<br> 18 20 2 0 0 0 0<br> 19 21 1 0 0 0 0<br> 19 29 1 0 0 0 0<br> 20 22 1 0 0 0 0<br> 20 30 1 0 0 0 0<br> 21 22 2 0 0 0 0<br> 21 31 1 0 0 0 0<br> 22 32 1 0 0 0 0<br>M CHG 2 3 -1 7 1<br>M END
Compound Name
Clonazepam
CID
2802
Molecular Formula
C15H10ClN3O3
Molecular Weight
315
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS
Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea
25864
Benzodiazepines extracted using Strata Screen C 150mg/3cc from Blood (TIC)
23894
Benzodiazepines extracted using Strata Screen C 150mg/3cc from Urine (TIC)
23893
Reversed Phase
7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea
23560
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm
Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
23445
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23444
Reversed Phase
Drugs of Abuse by LCMS using Luna Omega 1.6u C18 50x2.1mm
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
23443
Reversed Phase
Fast Pain Panel ESI+
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea
23384
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22122
Reversed Phase
Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22121
Reversed Phase
Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm
Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22120
Reversed Phase
Pain Panel Benzodiazapines using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22109
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22104
Reversed Phase
Pain Panel using Strata-X-Drug B and Kinetex Phenyl-Hexyl 2.6u 50x4.6mm
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea
20847
Reversed Phase
Pain Panel Mix-41 in Human Urine on Luna 3u, PFP(2), 50x3 by LC-MS/MS
Luna 3 µm PFP(2) 100 Å, LC Column 50 x 3 mm, Ea
20594
Reversed Phase
Separation of Benzodiazepines
Synergi 4 µm Hydro-RP 80 Å, LC Column 50 x 2 mm, Ea
20047
Reversed Phase
Benzodiazepines using Kinetex 2.6u C18 50x2.1mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19906
Reversed Phase
Benzodiazepines using Kinetex 2.6u Phenyl-Hexyl 50x2.1mm
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2.1 mm, Ea
19904
Reversed Phase
Benzodiazepines from urine using Strata-X-Drug N on a Kinetex C18 2.6µm, 50x2.1mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19714
Reversed Phase
Extraction of Benzodiazepines Using Strata Screen-C on Kinetex 2.6µm C18 50 x 2.1mm ID by LCMS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18849
Application Specific
Benzodiazepines(with extra internal standards) by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18779
Application Specific
Benzodiazepines from urine by Screen C on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18055
Benzodiazepines by MSD on a ZB-5MSi
17894
Standard
Benzodiazepines by MSD on a ZB-5MS
Zebron ZB-5MS, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
17893
Application Specific
Benzodiazepines by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
17808
Benzodiazepines by MSD on a ZB-1MS
17620
Benzodiazepines by MSD on a ZB-XLB
17619
Reversed Phase
MercuryMS - Luna 3µm C18(2) 20 x 2.0mm for Benzodiazepines in Plasma by LC/MS/MS
Luna 3 µm C18(2) 100 Å, LC Column 20 x 2 mm, MercuryMS, Ea
16040
Reversed Phase
Benzodiazepines on Synergi 2.5µm Max-RP 20 x 2.0mm Mini-Column
Synergi 2.5 µm Max-RP 100 Å, LC Column 20 x 2 mm, MercuryMS, Ea
15463
Reversed Phase
Benzodiazepines Standards on Gemini C18
Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea
15456
Reversed Phase
Benzodiazepines (SPE-Plasma) on Hybrid C18 Column
Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea
15454