Diazepam and related compounds on Synergi Polar-RP in Methanol

Diazepam and related compounds on Synergi Polar-RP in Methanol
LC Conditions
Column

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea

Brand

Synergi

Part No

00F-4336-E0

Phase Name

Polar-RP

Elution Type

Isocratic

Mobile Phase

A: Methanol

B: 20mM Potassium phosphate pH 2.5

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

70

30

Flow Rate

1.50 mL/min

Temperature

30°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, POLAR-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-6076 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea
00F-4336-E0

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Clonazepam
  • 2. Desmethyldiazepam
  • 3. Temazepam
  • 4. Diazepam
-OEChem-06211003152D<br><br> 32 34  0     0  0  0  0  0  0999 V2000<br>    5.5096    0.5528    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.8430    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9123   -0.6327    0.0000 O   0  5  0  0  0  0  0  0  0  0  0  0<br>    7.0405    0.8640    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5984   -2.2836    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6235   -0.2592    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0444   -0.1360    0.0000 N   0  3  0  0  0  0  0  0  0  0  0  0<br>    4.3802   -0.6602    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3802   -1.6602    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5984   -0.0367    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8209    0.9383    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2742   -0.1255    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2742   -2.1948    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1896   -1.1602    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1803   -0.6393    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6235   -2.0611    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1803   -1.6810    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7765    1.2330    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0879    1.6184    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9990    2.2079    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.3104    2.5934    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2660    2.8881    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2670    0.4945    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7364   -2.8881    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2670   -2.8148    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7049   -0.7736    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7049   -1.5467    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7160   -1.9930    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.4954    1.4357    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5915    2.3907    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8559    3.0151    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4039    3.4926    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 18  1  0  0  0  0<br>  2 16  2  0  0  0  0<br>  3  7  1  0  0  0  0<br>  4  7  2  0  0  0  0<br>  5  9  1  0  0  0  0<br>  5 16  1  0  0  0  0<br>  5 24  1  0  0  0  0<br>  6 10  2  0  0  0  0<br>  6 14  1  0  0  0  0<br>  7 15  1  0  0  0  0<br>  8  9  2  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 12  1  0  0  0  0<br>  9 13  1  0  0  0  0<br> 10 11  1  0  0  0  0<br> 11 18  1  0  0  0  0<br> 11 19  2  0  0  0  0<br> 12 15  2  0  0  0  0<br> 12 23  1  0  0  0  0<br> 13 17  2  0  0  0  0<br> 13 25  1  0  0  0  0<br> 14 16  1  0  0  0  0<br> 14 26  1  0  0  0  0<br> 14 27  1  0  0  0  0<br> 15 17  1  0  0  0  0<br> 17 28  1  0  0  0  0<br> 18 20  2  0  0  0  0<br> 19 21  1  0  0  0  0<br> 19 29  1  0  0  0  0<br> 20 22  1  0  0  0  0<br> 20 30  1  0  0  0  0<br> 21 22  2  0  0  0  0<br> 21 31  1  0  0  0  0<br> 22 32  1  0  0  0  0<br>M  CHG  2   3  -1   7   1<br>M  END
Compound Name

Clonazepam

CID

2802

Molecular Formula

C15H10ClN3O3

Molecular Weight

315

No. Hydrogen Bond Acceptors

4

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS

Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea

25864

Benzodiazepines extracted using Strata Screen C 150mg/3cc from Blood (TIC)

23894

Benzodiazepines extracted using Strata Screen C 150mg/3cc from Urine (TIC)

23893

Reversed Phase

7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea

23560

Reversed Phase

Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

23445

Reversed Phase

Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm

Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

23444

Reversed Phase

Drugs of Abuse by LCMS using Luna Omega 1.6u C18 50x2.1mm

Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA

23443

Reversed Phase

Fast Pain Panel ESI+

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea

23384

Reversed Phase

Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

22122

Reversed Phase

Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22121

Reversed Phase

Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm

Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22120

Reversed Phase

Pain Panel Benzodiazapines using Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22109

Reversed Phase

Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22104

Reversed Phase

Pain Panel using Strata-X-Drug B and Kinetex Phenyl-Hexyl 2.6u 50x4.6mm

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea

20847

Reversed Phase

Pain Panel Mix-41 in Human Urine on Luna 3u, PFP(2), 50x3 by LC-MS/MS

Luna 3 µm PFP(2) 100 Å, LC Column 50 x 3 mm, Ea

20594

Reversed Phase

Separation of Benzodiazepines

Synergi 4 µm Hydro-RP 80 Å, LC Column 50 x 2 mm, Ea

20047

Reversed Phase

Benzodiazepines using Kinetex 2.6u C18 50x2.1mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19906

Reversed Phase

Benzodiazepines using Kinetex 2.6u Phenyl-Hexyl 50x2.1mm

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2.1 mm, Ea

19904

Reversed Phase

Benzodiazepines from urine using Strata-X-Drug N on a Kinetex C18 2.6µm, 50x2.1mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19714

Reversed Phase

Extraction of Benzodiazepines Using Strata Screen-C on Kinetex 2.6µm C18 50 x 2.1mm ID by LCMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18849

Application Specific

Benzodiazepines(with extra internal standards) by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18779

Application Specific

Benzodiazepines from urine by Screen C on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18055

Benzodiazepines by MSD on a ZB-5MSi

17894

Standard

Benzodiazepines by MSD on a ZB-5MS

Zebron ZB-5MS, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

17893

Application Specific

Benzodiazepines by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

17808

Benzodiazepines by MSD on a ZB-1MS

17620

Benzodiazepines by MSD on a ZB-XLB

17619

Reversed Phase

MercuryMS - Luna 3µm C18(2) 20 x 2.0mm for Benzodiazepines in Plasma by LC/MS/MS

Luna 3 µm C18(2) 100 Å, LC Column 20 x 2 mm, MercuryMS, Ea

16040

Reversed Phase

Benzodiazepines on Synergi 2.5µm Max-RP 20 x 2.0mm Mini-Column

Synergi 2.5 µm Max-RP 100 Å, LC Column 20 x 2 mm, MercuryMS, Ea

15463

Reversed Phase

Benzodiazepines Standards on Gemini C18

Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea

15456

Reversed Phase

Benzodiazepines (SPE-Plasma) on Hybrid C18 Column

Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea

15454