Siberian Ginseng extract on Synergi Polar-RP

Siberian Ginseng extract on Synergi Polar-RP
LC Conditions
Column

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea

Brand

Synergi

Part No

00F-4336-E0

Phase Name

Polar-RP

Elution Type

Gradient

Mobile Phase

A: Water

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

90

10

2

20

78

22

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, POLAR-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-6076 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea
00F-4336-E0

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Eleutheroside B
  • 2. Eleutheroside E
Similar Applications

No Similar applications found.