Milk on Luna Amino
LC Conditions
Column
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
Brand
Luna
Part No
00G-4378-E0
Phase Name
NH2
Elution Type
Isocratic
Mobile Phase
A: Acetonitrile
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
80
20
Flow Rate
3.00 mL/min
Temperature
40°C
Detection
Refractive Index (RI) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, NH2 4 x 3.0mm, 10/Pk Part No.: AJ0-4302 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Lactose
-OEChem-06211003152D<br><br> 45 46 0 1 0 0 0 0 0999 V2000<br> 6.8671 -0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 2.0000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5991 0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 -2.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -3.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -2.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5991 2.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 3.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 1.0000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -1.0000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 0.5000 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 7.7331 1.0000 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.0010 -1.0000 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 6.0010 1.0000 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.0010 -2.0000 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 5.1350 -2.5000 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.0000 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.0000 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 7.7331 2.0000 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 6.8671 2.5000 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 5.1350 0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 0.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 0.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5380 -1.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5380 -1.6900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6720 -2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 2.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7365 0.0251 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5335 0.0251 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8015 -0.0251 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.0044 -0.0251 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.1360 0.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 -3.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -3.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5991 3.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 1.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.6900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 12 1 1 6 0 0 0<br> 14 1 1 1 0 0 0<br> 2 14 1 0 0 0 0<br> 2 19 1 0 0 0 0<br> 3 15 1 0 0 0 0<br> 3 21 1 0 0 0 0<br> 13 4 1 1 0 0 0<br> 4 38 1 0 0 0 0<br> 16 5 1 6 0 0 0<br> 5 39 1 0 0 0 0<br> 17 6 1 1 0 0 0<br> 6 40 1 0 0 0 0<br> 18 7 1 1 0 0 0<br> 7 41 1 0 0 0 0<br> 20 8 1 6 0 0 0<br> 8 42 1 0 0 0 0<br> 21 9 1 1 0 0 0<br> 9 43 1 0 0 0 0<br> 10 22 1 0 0 0 0<br> 10 44 1 0 0 0 0<br> 11 23 1 0 0 0 0<br> 11 45 1 0 0 0 0<br> 12 13 1 0 0 0 0<br> 12 15 1 0 0 0 0<br> 12 24 1 0 0 0 0<br> 13 20 1 0 0 0 0<br> 13 25 1 0 0 0 0<br> 14 16 1 0 0 0 0<br> 14 26 1 0 0 0 0<br> 15 22 1 1 0 0 0<br> 15 27 1 0 0 0 0<br> 16 17 1 0 0 0 0<br> 16 28 1 0 0 0 0<br> 17 18 1 0 0 0 0<br> 17 29 1 0 0 0 0<br> 18 19 1 0 0 0 0<br> 18 30 1 0 0 0 0<br> 19 23 1 1 0 0 0<br> 19 31 1 0 0 0 0<br> 20 21 1 0 0 0 0<br> 20 32 1 0 0 0 0<br> 21 33 1 0 0 0 0<br> 22 34 1 0 0 0 0<br> 22 35 1 0 0 0 0<br> 23 36 1 0 0 0 0<br> 23 37 1 0 0 0 0<br>M END
Compound Name
Lactose
CID
6134
Molecular Formula
C12H22O11
Molecular Weight
342
No. Hydrogen Bond Acceptors
11
No. Hydrogen Bond Donors
8
Similar Applications
Application Specific
TMS Sugars on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16248
Ion Exclusion
Fermentation yeast sample using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14990
Ion Exclusion
Fermentation sample #3 using Rexex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14989
Ion Exclusion
Fermentation sample #2 using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14988
Ion Exclusion
Fermentation sample #1 using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14987
Ion Exclusion
Sugar analysis using Rezex RCM
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
14977
Ion Exclusion
Wood saccharides using Rezex RPM
Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea
14967
Normal Phase
Milk on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14292
Normal Phase
Simple Sugars (#4) on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14286
Normal Phase
Simple Sugars (#2) on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14284
Ion Exclusion
Saccharides
Rezex RPM-Monosaccharide Pb+2 (8%), LC Column 300 x 7.8 mm, Ea
5508