Wine on Luna Amino
LC Conditions
Column
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
Brand
Luna
Part No
00G-4378-E0
Phase Name
NH2
Elution Type
Isocratic
Mobile Phase
A: Acetonitrile
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
80
20
Flow Rate
3.00 mL/min
Temperature
40°C
Detection
Refractive Index (RI) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, NH2 4 x 3.0mm, 10/Pk Part No.: AJ0-4302 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Ethanol
- 2. unknown
- 3. Fructose
- 4. Glucose
- 5. Sucrose
-OEChem-06211003142D<br><br> 9 8 0 0 0 0 0 0 0999 V2000<br> 2.5369 -0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8015 0.7249 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.0044 0.7249 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9590 -0.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8059 -0.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5790 0.2869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 2 1 0 0 0 0<br> 1 9 1 0 0 0 0<br> 2 3 1 0 0 0 0<br> 2 4 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 8 1 0 0 0 0<br>M END
Compound Name
Ethanol
CID
702
Molecular Formula
C2H6O
Molecular Weight
46
No. Hydrogen Bond Acceptors
1
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Preservatives Analysis using Luna 3µm C18(2) 100x4.6mm
Luna 3 µm C18(2) 100 Å, LC Column 100 x 4.6 mm, Ea
19500
Improved Performance
Italian Wines using ZB-WAX and FID
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
18299
Ion Exclusion
Beer Well Drop on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16647
Ion Exclusion
25 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16646
Ion Exclusion
10 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16645
Ion Exclusion
6 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16644
Ion Exclusion
Yeast Prop. on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16643
Improved Performance
Cognacs: Hennessey® on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16359
Improved Performance
Cognacs: Courvoisier® on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16358
Standard
Cognac Standard on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16326
Improved Performance
Cognac Standard on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16325
Improved Performance
Cognac Standard (Headspace) on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16324
Standard
Glenfiddich® Scotch Whiskey on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
16047
Improved Performance
Glenfiddich® Scotch Whiskey on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16046
Standard
Scotch Whiskey Main Compounds on ZB-624
Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea
16045
Standard
Glenfiddich® Scotch Whiskey on ZB-624
Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea
16044
Standard
Flavors Analysis ZB-WAX 30x0.25x0.25
Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14900
Standard
Flavors Analysis ZB-FFAP 30x0.25x0.25
Zebron ZB-FFAP, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14899
Normal Phase
Wine on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14295
Ion Exclusion
Sugars in Cucumber Juice on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
3147