Wine on Luna Amino

Wine on Luna Amino
LC Conditions
Column

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

Brand

Luna

Part No

00G-4378-E0

Phase Name

NH2

Elution Type

Isocratic

Mobile Phase

A: Acetonitrile

B: Water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

80

20

Flow Rate

3.00 mL/min

Temperature

40°C

Detection

Refractive Index (RI) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, NH2 4 x 3.0mm, 10/Pk Part No.: AJ0-4302 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
00G-4378-E0

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Ethanol
  • 2. unknown
  • 3. Fructose
  • 4. Glucose
  • 5. Sucrose
-OEChem-06211003142D<br><br>  9  8  0     0  0  0  0  0  0999 V2000<br>    2.5369   -0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8015    0.7249    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0044    0.7249    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9590   -0.7869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8059   -0.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5790    0.2869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  2  1  0  0  0  0<br>  1  9  1  0  0  0  0<br>  2  3  1  0  0  0  0<br>  2  4  1  0  0  0  0<br>  2  5  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3  7  1  0  0  0  0<br>  3  8  1  0  0  0  0<br>M  END
Compound Name

Ethanol

CID

702

Molecular Formula

C2H6O

Molecular Weight

46

No. Hydrogen Bond Acceptors

1

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

Preservatives Analysis using Luna 3µm C18(2) 100x4.6mm

Luna 3 µm C18(2) 100 Å, LC Column 100 x 4.6 mm, Ea

19500

Improved Performance

Italian Wines using ZB-WAX and FID

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

18299

Ion Exclusion

Beer Well Drop on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16647

Ion Exclusion

25 Hr on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16646

Ion Exclusion

10 Hr on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16645

Ion Exclusion

6 Hr on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16644

Ion Exclusion

Yeast Prop. on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

16643

Improved Performance

Cognacs: Hennessey® on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16359

Improved Performance

Cognacs: Courvoisier® on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16358

Standard

Cognac Standard on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16326

Improved Performance

Cognac Standard on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16325

Improved Performance

Cognac Standard (Headspace) on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16324

Standard

Glenfiddich® Scotch Whiskey on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

16047

Improved Performance

Glenfiddich® Scotch Whiskey on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16046

Standard

Scotch Whiskey Main Compounds on ZB-624

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

16045

Standard

Glenfiddich® Scotch Whiskey on ZB-624

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

16044

Standard

Flavors Analysis ZB-WAX 30x0.25x0.25

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14900

Standard

Flavors Analysis ZB-FFAP 30x0.25x0.25

Zebron ZB-FFAP, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14899

Normal Phase

Wine on Luna Amino

Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea

14295

Ion Exclusion

Sugars in Cucumber Juice on Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

3147