Estrogens on Luna Amino
LC Conditions
Column
Luna 5 µm NH2 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4378-E0
Phase Name
NH2
Elution Type
Isocratic
Mobile Phase
A: Hexane
B: Isopropyl Alcohol
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
70
30
Flow Rate
2.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, NH2 4 x 3.0mm, 10/Pk Part No.: AJ0-4302 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Estrone
- 2. beta-Estradiol
- 3. Diethylstilbestrol
- 4. Estriol
-OEChem-06211003152D<br><br> 42 45 0 1 0 0 0 0 0999 V2000<br> 9.1857 2.1767 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5357 -2.1309 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9288 -0.0785 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 7.9288 0.9215 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 7.0628 -0.5785 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.1968 -0.0785 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 7.0628 1.4215 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.8750 -0.3833 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1968 0.9215 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0789 -1.6200 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.8750 1.2262 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4586 0.4215 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9288 1.9215 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2868 -0.5854 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1808 -2.1478 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2787 -1.6270 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3599 -0.0213 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3433 -2.1767 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4120 -0.5493 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4037 -1.6342 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0188 -0.9238 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8022 -0.9979 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9329 0.3465 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4613 1.8964 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6643 1.8964 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6240 -0.9502 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4124 -0.6925 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9847 1.5041 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5862 0.8138 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2969 -2.2004 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6880 -1.5046 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9195 0.0067 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9195 0.8362 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5488 1.9215 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9288 2.5415 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3088 1.9215 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7835 -2.6238 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5818 -2.6207 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3719 0.5986 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3457 -2.7967 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8787 -0.2331 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.8188 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 11 2 0 0 0 0<br> 2 20 1 0 0 0 0<br> 2 42 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 3 21 1 6 0 0 0<br> 4 7 1 0 0 0 0<br> 4 11 1 0 0 0 0<br> 4 13 1 1 0 0 0<br> 5 6 1 0 0 0 0<br> 5 10 1 0 0 0 0<br> 5 22 1 1 0 0 0<br> 6 9 1 0 0 0 0<br> 6 14 1 0 0 0 0<br> 6 23 1 6 0 0 0<br> 7 9 1 0 0 0 0<br> 7 24 1 0 0 0 0<br> 7 25 1 0 0 0 0<br> 8 12 1 0 0 0 0<br> 8 26 1 0 0 0 0<br> 8 27 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 9 29 1 0 0 0 0<br> 10 15 1 0 0 0 0<br> 10 30 1 0 0 0 0<br> 10 31 1 0 0 0 0<br> 11 12 1 0 0 0 0<br> 12 32 1 0 0 0 0<br> 12 33 1 0 0 0 0<br> 13 34 1 0 0 0 0<br> 13 35 1 0 0 0 0<br> 13 36 1 0 0 0 0<br> 14 16 2 0 0 0 0<br> 14 17 1 0 0 0 0<br> 15 16 1 0 0 0 0<br> 15 37 1 0 0 0 0<br> 15 38 1 0 0 0 0<br> 16 18 1 0 0 0 0<br> 17 19 2 0 0 0 0<br> 17 39 1 0 0 0 0<br> 18 20 2 0 0 0 0<br> 18 40 1 0 0 0 0<br> 19 20 1 0 0 0 0<br> 19 41 1 0 0 0 0<br>M END
Compound Name
Estrone
CID
5870
Molecular Formula
C18H22O2
Molecular Weight
270
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
EPA 539 using Kinetex 5u EVO C18 100x3.0mm
Kinetex 5 µm EVO C18 100 Å, LC Column 100 x 3.0 mm, Ea
22780
Reversed Phase
Estradiol and estrone analysis by LCMS using Gemini 3um NX-C18 50x2mm
Gemini 3 µm NX-C18 110 Å, LC Column 50 x 2 mm, Ea
20653
Reversed Phase
Steroids Mix on Kinetex 2.6µ C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
19992
Reversed Phase
Steroids Mix on Kinetex 2.6µ Phenyl-Hexyl
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea
19991
Reversed Phase
Estrogen Mix using Kinetex 1.7u XB-C18 50x2.10mm on Water Acquity UPLC system
Kinetex 1.7 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19799
Reversed Phase
Estrone, Estradiol, and Estriol from Water @ pH 2.0 Strata-X via Kinetex XB-C18 150x4.60mm
Kinetex 2.6 µm XB-C18 100 Å, LC Column 150 x 4.6 mm, Ea
19680
Reversed Phase
Steroids Mix using Kinetex 2.6µm C8, 50x2.1mm
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19526
Reversed Phase
Steroids Mix using Kinetex 2.6µm C18 50x2.1mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19488
Reversed Phase
Steroids Mix using Kinetex 2.6u XB-C18, 50x2.1mm
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19487
Reversed Phase
Steroid Mixture on Kinetex 2.6µm C8 50x2.1mm ID
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19479
Reversed Phase
Steroid Mixture on Kinetex XB-C18 50x2.1mm ID
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19478
Reversed Phase
Steroid Mixture on Kinetex C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19477
Sex hormones on a ZB-1ms 30x0.25x0.25 by GCMS
19293
Reversed Phase
USP 621: Allowable changes in flow rate- 1.5 mL/Min
Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea
19165
Reversed Phase
USP 621: Allowable changes in flow rate- 1.0 mL/Min
Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea
19164
Reversed Phase
Selectivity Comparison for Steroids on Kinetex 2.6µm C18 150 x 4.6mm ID
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
18684
Reversed Phase
Steroids on Kinetex 2.6µm C18 150 x 4.6mm ID
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
18682
Reversed Phase
Steroids on Luna 3µm PFP(2) 50 x 2mm ID (in acetonitrile)
Luna 3 µm PFP(2) 100 Å, LC Column 50 x 2 mm, Ea
18508
Reversed Phase
Steroids on Kinetex 2.6µm C18 50 x 2.1mm ID (in acetonitrile)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18507
Hormones/Steroids by MSD on a ZB-5MSi
17935
Application Specific
Hormones/Steroids by MSD on a ZB-Drug-1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
17934
Reversed Phase
Luna - USP Estradiol#2
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16893
Reversed Phase
Max-RP - USP Estradiol
Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea
16892
Reversed Phase
Steroid Mix (11) on Luna 5um PFP(2)
Luna 5 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16291
Reversed Phase
Steroid Mix (11) on Luna 3um PFP(2)
Luna 3 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16290
Reversed Phase
Estradiol on Gemini 5um C18
Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
15847
Reversed Phase
Estradiol - USP Method (Synergi 4µm Fusion-RP)
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
15663
Steroids on Onyx C18 (3 columns coupled)
15648
Steroids on Onyx C18
15509
Reversed Phase
Steroids on Onyx C18
Onyx Monolithic C18, LC Column 50 x 4.6 mm, Ea
15477
Reversed Phase
Estradiol - USP Method
Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
15001
Normal Phase
Estrogens on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 150 x 4.6 mm, Ea
14298
Reversed Phase
Corticosteroids using Ammonium Hydroxide
Luna 3 µm C18(2) 100 Å, LC Column 30 x 4.6 mm, Ea
11073
Reversed Phase
Estradiol - USP Method
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
10893
Reversed Phase
USP Estradiol
Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea
10892
Reversed Phase
Corticosteroids using Ammonium Hydroxide
Luna 3 µm C18(2) 100 Å, LC Column 30 x 4.6 mm, Ea
10873
Reversed Phase
Estradiol - USP Acceptable Modified Method
Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea
8713