Extraction of Fenoprofen on Strata™ X

Extraction of Fenoprofen on Strata™ X
LC Conditions
Column

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Luna

Part No

00F-4249-E0

Phase Name

C8(2)

Elution Type

Isocratic

Mobile Phase

A: 0.05% H3PO4 (pH 2.3)

B: ACN

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

50

50

Flow Rate

1.50 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Fixed Wave. (UV) @ (25°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282

Sample Preparation Details
Description

Strata-X 33 µm Polymeric Reversed Phase, 30 mg / 1 mL, Tubes, 100/Pk

Part No

8B-S100-TAK

Condition 1

Methanol

Condition 2

Water

Load

Load 1.00 mL Sample diluted in Buffer

Wash 1

1.0 mL 5% methanol/D. I. water

Dry

1 min at 10 of Hg pressure

Elution 1

1.0 mL Methanol

Elution 2

Blow down to almost dryness under slow stream of N2.Reconstitute with mobile phase to 200 µL.

Evaporation

Evaporate to dryness

Reconstitute

2 mL Buffer

Order Items Used in This Application

Strata-X 33 µm Polymeric Reversed Phase, 30 mg / 1 mL, Tubes, 100/Pk
8B-S100-TAK

Strata-X 33 µm Polymeric Reversed Phase, 30 mg / 1 mL, Tubes, 100/Pk

View Product

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4249-E0

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Fenoprofen
  • 2. Indomethacine
-OEChem-06211003152D<br><br> 32 33  0     1  0  0  0  0  0999 V2000<br>    2.8660   -0.9050    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    3.5950    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    2.0950    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    2.0950    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    4.5981    1.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    2.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -0.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -3.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -3.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -3.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    2.9450    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1951    0.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0420    3.1319    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1951    2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4220    2.0581    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010    0.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010   -0.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -1.5250    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -2.0950    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -2.0950    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -3.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -3.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010    3.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -4.5250    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  1  0  0  0  0<br>  1 13  1  0  0  0  0<br>  2 10  1  0  0  0  0<br>  2 31  1  0  0  0  0<br>  3 10  2  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4  7  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  4 19  1  0  0  0  0<br>  5  6  2  0  0  0  0<br>  5  8  1  0  0  0  0<br>  6  9  1  0  0  0  0<br>  6 20  1  0  0  0  0<br>  7 21  1  0  0  0  0<br>  7 22  1  0  0  0  0<br>  7 23  1  0  0  0  0<br>  8 11  2  0  0  0  0<br>  8 24  1  0  0  0  0<br>  9 12  2  0  0  0  0<br> 11 12  1  0  0  0  0<br> 11 25  1  0  0  0  0<br> 12 26  1  0  0  0  0<br> 13 14  2  0  0  0  0<br> 13 15  1  0  0  0  0<br> 14 16  1  0  0  0  0<br> 14 27  1  0  0  0  0<br> 15 17  2  0  0  0  0<br> 15 28  1  0  0  0  0<br> 16 18  2  0  0  0  0<br> 16 29  1  0  0  0  0<br> 17 18  1  0  0  0  0<br> 17 30  1  0  0  0  0<br> 18 32  1  0  0  0  0<br>M  END
Compound Name

Fenoprofen

CID

3342

Molecular Formula

C15H14O3

Molecular Weight

242

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

1

Similar Applications

Chiral

Fenoprofen on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23328

Chiral

Fenoprofen on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23319

Chiral

Fenoprofen on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23279

Chiral

Fenoprofen on Lux 5µm Cellulose-4 by SFC

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21133

Chiral

Fenoprofen on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21132

Chiral

Fenoprofen on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21131

Fenoprofen on Lux 5µm Amylose-2 by SFC

21130

Fenoprofen on Lux 5µm Amylose-2 by SFC

21129

Fenoprofen on Lux 5µm Amylose-2 in NP

20453

Chiral

Fenoprofen on Lux 5µm Cellulose-3 in RP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20309

Reversed Phase

NSAID's in Human Urine using Kinetex 2.6 µ C8 150 x 2.10 mm on Shimadzu Nexera

Kinetex 2.6 µm C8 100 Å, LC Column 100 x 4.6 mm, Ea

19963

Reversed Phase

Veterinary Drugs in Horse Urine on Kinetex 2.6µm C8 50x4.6mm @ 2.00mL/min

Kinetex 2.6 µm C8 100 Å, LC Column 50 x 4.6 mm, Ea

19473

Reversed Phase

Veterinary Drugs in Horse Urine on Kinetex 2.6µm C8 50x4.6mm @ 1.50mL/min

Kinetex 2.6 µm C8 100 Å, LC Column 50 x 4.6 mm, Ea

19472

Reversed Phase

Veterinary Drugs in Horse Urine on Luna 3µm C8(2) 100x4.6mm

Luna 3 µm C8(2) 100 Å, LC Column 100 x 4.6 mm, Ea

19471

Reversed Phase

Veterinary Drugs in Horse Urine on Luna 3µm C18(2) 100x4.6mm

Luna 3 µm C18(2) 100 Å, LC Column 100 x 4.6 mm, Ea

19467

Reversed Phase

Veterinary Drugs in Horse Urine on Kinetex 2.6µm C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

19466

Reversed Phase

Veterinary Drugs in Horse Urine on Kinetex 2.6µm C8 100x4.6mm

Kinetex 2.6 µm C8 100 Å, LC Column 100 x 4.6 mm, Ea

19465

Reversed Phase

Extraction of Analgesics from Plasma Using Strata X-A on Kinetex 2.6u, C18, 50x2.1mm by LC-UV

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19246

NSAIDs on Onyx C18 (Luna Comparison)

15649

Reversed Phase

Extraction of Fenoprofen on Strata™ X

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

14455

Reversed Phase

Anti-inflammatory/Analgesics

Luna 3 µm C8(2) 100 Å, LC Column 75 x 4.6 mm, Ea

12927

Reversed Phase

Anti-inflammatory/Analgesic Drugs

Luna 3 µm C18(2) 100 Å, LC Column 75 x 4.6 mm, Ea

12903

Reversed Phase

Anti-inflammatory/Analgesic Drugs

Luna 3 µm C8(2) 100 Å, LC Column 75 x 4.6 mm, Ea

1226

Reversed Phase

Anti-inflammatory/Analgesic Drugs

Luna 3 µm C8(2) 100 Å, LC Column 75 x 4.6 mm, Ea

1209