Fluoropharmaceuticals using Synergi Fusion-RP
LC Conditions
Column
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
Brand
Synergi
Part No
00F-4424-E0
Phase Name
Fusion-RP
Elution Type
Isocratic
Mobile Phase
A: 20mm Potassium Phosphate, pH 2.5
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
50
50
Flow Rate
1.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Fusion-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-7557 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Flurbiprofen
- 2. Diflunisal
-OEChem-06211003152D<br><br> 31 32 0 1 0 0 0 0 0999 V2000<br> 2.0000 0.9050 0.0000 F 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.5950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.0950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.0950 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 3.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 3.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.9450 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -0.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 0.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5560 -2.0581 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1760 -3.1319 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 2.0950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 2.0950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 3.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 3.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 4.5250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -3.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 2 13 1 0 0 0 0<br> 2 31 1 0 0 0 0<br> 3 13 2 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 11 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 19 1 0 0 0 0<br> 5 7 2 0 0 0 0<br> 5 8 1 0 0 0 0<br> 6 9 2 0 0 0 0<br> 6 10 1 0 0 0 0<br> 6 12 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 20 1 0 0 0 0<br> 8 10 2 0 0 0 0<br> 8 21 1 0 0 0 0<br> 10 22 1 0 0 0 0<br> 11 23 1 0 0 0 0<br> 11 24 1 0 0 0 0<br> 11 25 1 0 0 0 0<br> 12 14 2 0 0 0 0<br> 12 15 1 0 0 0 0<br> 14 16 1 0 0 0 0<br> 14 26 1 0 0 0 0<br> 15 17 2 0 0 0 0<br> 15 27 1 0 0 0 0<br> 16 18 2 0 0 0 0<br> 16 28 1 0 0 0 0<br> 17 18 1 0 0 0 0<br> 17 29 1 0 0 0 0<br> 18 30 1 0 0 0 0<br>M END
Compound Name
Flurbiprofen
CID
3394
Molecular Formula
C15H13FO2
Molecular Weight
244
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Similar Applications
Chiral
Lux i-Amylose-3 Separation for Flurbiprofen
Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea
25352
Chiral
Flurbiprofen on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23298
Chiral
Flurbiprofen on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23285
Chiral
Flurbiprofen on LUX Amylose-1 5u in RP
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23206
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21139
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21138
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21137
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21136
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21135
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21134
NSAIDs on Onyx C18 (Luna Comparison)
15649
Reversed Phase
Fluoropharmaceuticals using Synergi Fusion-RP
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
14846