Aniline - Phenol Separation - ZB-Wax 60x0.32x0.5

Aniline - Phenol Separation - ZB-Wax 60x0.32x0.5
GC Conditions
Column

Zebron ZB-WAX, GC Cap. Column 60 m x 0.32 mm x 0.50 µm, Ea

Part No

7KM-G007-17

Phase Name

ZB-WAX

Injection

Split 20:1 @ 275°C

Carrier Gas

Constant Flow Helium, 0.9 mL/min

Detection

Mass Selective (MSD) @ (240°C)

Detection Info

Order Items Used in This Application

Zebron ZB-WAX, GC Cap. Column 60 m x 0.32 mm x 0.50 µm, Ea
7KM-G007-17

Zebron ZB-WAX, GC Cap. Column 60 m x 0.32 mm x 0.50 µm, Ea

View Product

  • 1. Aniline
  • 2. Phenol
-OEChem-06211003152D<br><br> 14 14  0     0  0  0  0  0  0999 V2000<br>    2.8660    1.3450    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.3450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.6550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.4650    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.4650    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.2750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030    1.6550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.6550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  2  1  0  0  0  0<br>  1 13  1  0  0  0  0<br>  1 14  1  0  0  0  0<br>  2  3  2  0  0  0  0<br>  2  4  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  8  1  0  0  0  0<br>  4  6  2  0  0  0  0<br>  4  9  1  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5 10  1  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6 11  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>M  END
Compound Name

Aniline

CID

6115

Molecular Formula

C6H7N

Molecular Weight

93

No. Hydrogen Bond Acceptors

1

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

USP Ezetimibe Organic Impurities Standard Solution 0.25mg/mL on Kinetex 5u F5 150x4.6mm on Agilent 1260 Quaternary UHPLC system

Kinetex 5 µm F5 100 Å, LC Column 150 x 4.6 mm, Ea

27755

Improved Performance

Zebon ZB-624PLUS QC Test Mix

Zebron ZB-624plus, GC Cap. Column 30m x 0.32mm x 1.8um, Ea

25001

Reversed Phase

Carcinogenic amines on Kinetex 2.6 µm EVO C18

Kinetex 2.6 µm EVO C18 100 Å, LC Column 150 x 2.1 mm, EA

23042

Reversed Phase

Customer high pH study using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22731

Application Specific

EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

20582

Application Specific

Fast EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea

20572

Application Specific

Fast Amines on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea

20571

High Temperature

EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT

Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

18785

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18152

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18151

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18149

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18148

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18147

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18146

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18145

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 3u Phenyl Hexyl

Luna 3 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2 mm, Ea

17981

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi 2.5u Hydro Rp

Synergi 2.5 µm Hydro-RP 100 Å, LC Column 100 x 2 mm, Ea

17980

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi 2.5u Polar Rp

Synergi 2.5 µm Polar-RP 100 Å, LC Column 100 x 2 mm, Ea

17979

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini 5u NX

Gemini 5 µm NX-C18 110 Å, LC Column 250 x 4.6 mm, Ea

17959

Normal Phase

EPA Method 8330: Explosive Mix Using Hyperclone 5u CN

HyperClone 5 µm CN (CPS) 120 Å, LC Column 250 x 4.6 mm, Ea

17958

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini C6 Phenyl

Gemini 5 µm C6-Phenyl 110 Å, LC Column 250 x 4.6 mm, Ea

17957

Reversed Phase

EPA Method 8330: Explosive Mix Using Hyperclone ODS C18

HyperClone 5 µm ODS (C18) 120 Å, LC Column 250 x 4.6 mm, Ea

17956

Normal Phase

EPA Method 8330: Explosive mix Using Luna 5u CN

Luna 5 µm CN 100 Å, LC Column 250 x 4.6 mm, Ea

17955

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 5u PFP

Luna 5 µm PFP(2) 100 Å, LC Column 250 x 4.6 mm, Ea

17954

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini 5u C18

Gemini 5 µm C18 110 Å, LC Column 250 x 4.6 mm, Ea

17953

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 5u C18

Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea

17952

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Polar RP

Synergi 4 µm Polar-RP 80 Å, LC Column 250 x 4.6 mm, Ea

17951

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

17913

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

17912

Standard

EPA Method 8270C on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16584

EPA Method 8270C ZB-5MSi

16413

Application Specific

EPA Method 8270C on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16275

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea

15696

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15695

Standard

Nitrosamines on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14959

Standard

EPA Method 8270C on ZB-5MS 30x0.25x0.25

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14953

Standard

EPA Method 8270C on Guardian on ZB-5

Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14945

Standard

Aromatic Amines on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14790

Standard

Aromatic Amines on ZB-1701

Zebron ZB-1701, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14789

Standard

8270 Semi-Volatile Organic Analysis on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14567

Standard

Semivolatiles (BNA) by GC/MS (EPA Method 8270C)

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea

14442