Aniline - Phenol Separation - ZB-Wax 60x0.32x0.5
GC Conditions
Column
Zebron ZB-WAX, GC Cap. Column 60 m x 0.32 mm x 0.50 µm, Ea
Part No
7KM-G007-17
Phase Name
ZB-WAX
Injection
Split 20:1 @ 275°C
Carrier Gas
Constant Flow Helium, 0.9 mL/min
Detection
Mass Selective (MSD) @ (240°C)
Detection Info
Order Items Used in This Application
- 1. Aniline
- 2. Phenol
-OEChem-06211003152D<br><br> 14 14 0 0 0 0 0 0 0999 V2000<br> 2.8660 1.3450 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.4650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.4650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.2750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 1.6550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 1.6550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 2 1 0 0 0 0<br> 1 13 1 0 0 0 0<br> 1 14 1 0 0 0 0<br> 2 3 2 0 0 0 0<br> 2 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 4 6 2 0 0 0 0<br> 4 9 1 0 0 0 0<br> 5 7 2 0 0 0 0<br> 5 10 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 11 1 0 0 0 0<br> 7 12 1 0 0 0 0<br>M END
Compound Name
Aniline
CID
6115
Molecular Formula
C6H7N
Molecular Weight
93
No. Hydrogen Bond Acceptors
1
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
USP Ezetimibe Organic Impurities Standard Solution 0.25mg/mL on Kinetex 5u F5 150x4.6mm on Agilent 1260 Quaternary UHPLC system
Kinetex 5 µm F5 100 Å, LC Column 150 x 4.6 mm, Ea
27755
Improved Performance
Zebon ZB-624PLUS QC Test Mix
Zebron ZB-624plus, GC Cap. Column 30m x 0.32mm x 1.8um, Ea
25001
Reversed Phase
Carcinogenic amines on Kinetex 2.6 µm EVO C18
Kinetex 2.6 µm EVO C18 100 Å, LC Column 150 x 2.1 mm, EA
23042
Reversed Phase
Customer high pH study using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22731
Application Specific
EPA Method 8270D on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
20582
Application Specific
Fast EPA Method 8270D on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea
20572
Application Specific
Fast Amines on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea
20571
High Temperature
EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
18785
Reversed Phase
EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea
18152
Reversed Phase
EPA Method 8330: Explosive Mix Using Synergi Hydro-RP
Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea
18151
Reversed Phase
EPA Method 8330: Explosive Mix Using Synergi Hydro-RP
Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea
18149
Reversed Phase
EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea
18148
Reversed Phase
EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea
18147
Reversed Phase
EPA Method 8330: Explosive Mix Using Synergi Hydro-RP
Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea
18146
Reversed Phase
EPA Method 8330: Explosive Mix Using Synergi Hydro-RP
Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea
18145
Reversed Phase
EPA Method 8330: Explosive Mix Using Luna 3u Phenyl Hexyl
Luna 3 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2 mm, Ea
17981
Reversed Phase
EPA Method 8330: Explosive Mix Using Synergi 2.5u Hydro Rp
Synergi 2.5 µm Hydro-RP 100 Å, LC Column 100 x 2 mm, Ea
17980
Reversed Phase
EPA Method 8330: Explosive Mix Using Synergi 2.5u Polar Rp
Synergi 2.5 µm Polar-RP 100 Å, LC Column 100 x 2 mm, Ea
17979
Reversed Phase
EPA Method 8330: Explosive Mix Using Gemini 5u NX
Gemini 5 µm NX-C18 110 Å, LC Column 250 x 4.6 mm, Ea
17959
Normal Phase
EPA Method 8330: Explosive Mix Using Hyperclone 5u CN
HyperClone 5 µm CN (CPS) 120 Å, LC Column 250 x 4.6 mm, Ea
17958
Reversed Phase
EPA Method 8330: Explosive Mix Using Gemini C6 Phenyl
Gemini 5 µm C6-Phenyl 110 Å, LC Column 250 x 4.6 mm, Ea
17957
Reversed Phase
EPA Method 8330: Explosive Mix Using Hyperclone ODS C18
HyperClone 5 µm ODS (C18) 120 Å, LC Column 250 x 4.6 mm, Ea
17956
Normal Phase
EPA Method 8330: Explosive mix Using Luna 5u CN
Luna 5 µm CN 100 Å, LC Column 250 x 4.6 mm, Ea
17955
Reversed Phase
EPA Method 8330: Explosive Mix Using Luna 5u PFP
Luna 5 µm PFP(2) 100 Å, LC Column 250 x 4.6 mm, Ea
17954
Reversed Phase
EPA Method 8330: Explosive Mix Using Gemini 5u C18
Gemini 5 µm C18 110 Å, LC Column 250 x 4.6 mm, Ea
17953
Reversed Phase
EPA Method 8330: Explosive Mix Using Luna 5u C18
Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea
17952
Reversed Phase
EPA Method 8330: Explosive Mix Using Synergi Polar RP
Synergi 4 µm Polar-RP 80 Å, LC Column 250 x 4.6 mm, Ea
17951
Reversed Phase
EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea
17913
Reversed Phase
EPA Method 8330: Explosive Mix Using Synergi Hydro-RP
Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea
17912
Standard
EPA Method 8270C on ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16584
EPA Method 8270C ZB-5MSi
16413
Application Specific
EPA Method 8270C on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16275
Standard
EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea
15696
Standard
EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
15695
Standard
Nitrosamines on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14959
Standard
EPA Method 8270C on ZB-5MS 30x0.25x0.25
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14953
Standard
EPA Method 8270C on Guardian on ZB-5
Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14945
Standard
Aromatic Amines on ZB-5
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14790
Standard
Aromatic Amines on ZB-1701
Zebron ZB-1701, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14789
Standard
8270 Semi-Volatile Organic Analysis on ZB-5
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14567
Standard
Semivolatiles (BNA) by GC/MS (EPA Method 8270C)
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea
14442