Nitroaromatics - EPA Method 609: ZB-5 15x0.53x1.5

Nitroaromatics - EPA Method 609: ZB-5 15x0.53x1.5
GC Conditions
Official Method

EPA 609

Column

Zebron ZB-5, GC Cap. Column 15 m x 0.53 mm x 1.50 µm, Ea

Part No

7EK-G002-28

Phase Name

ZB-5

Injection

Split 15:1 @ 250°C

Carrier Gas

Constant Flow Helium, 3.0 mL/min

Detection

Flame Ionization (FID) @ (300°C)

Detection Info

Order Items Used in This Application

Zebron ZB-5, GC Cap. Column 15 m x 0.53 mm x 1.50 µm, Ea
7EK-G002-28

Zebron ZB-5, GC Cap. Column 15 m x 0.53 mm x 1.50 µm, Ea

View Product

  • 1. Nitrobenzene
  • 2. Isophorone
  • 3. 2,6-Dinitrotoluene
  • 4. 2,4-Dinitrotoluene
-OEChem-06211003152D<br><br> 14 14  0     0  0  0  0  0  0999 V2000<br>    3.7320    1.7500    0.0000 O   0  5  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.7500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.2500    0.0000 N   0  3  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  3  1  0  0  0  0<br>  2  3  2  0  0  0  0<br>  3  4  1  0  0  0  0<br>  4  5  2  0  0  0  0<br>  4  6  1  0  0  0  0<br>  5  7  1  0  0  0  0<br>  5 10  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6 11  1  0  0  0  0<br>  7  9  2  0  0  0  0<br>  7 12  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 13  1  0  0  0  0<br>  9 14  1  0  0  0  0<br>M  CHG  2   1  -1   3   1<br>M  END
Compound Name

Nitrobenzene

CID

7416

Molecular Formula

C6H5NO2

Molecular Weight

123

No. Hydrogen Bond Acceptors

2

Similar Applications

Reversed Phase

EPA 8330A on Kinetex 2.6u Polar C18 100x4.6mm

Kinetex 2.6 µm Polar C18 100 Å, LC Column 100 x 4.6 mm, Ea

24157

Reversed Phase

Explosives Mix on Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

23094

Application Specific

EPA 508 by GC/ECD on ZB-CLPesticides-2 (Helium Gas)

Zebron ZB-CLPesticides-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

22636

Application Specific

EPA 508 by GC/ECD on ZB-CLPesticides-1 (Helium Gas)

Zebron ZB-CLPesticides-1, GC Cap. Column 30 m x 0.32 mm x 0.32 µm, Ea

22635

Application Specific

Chlorinated Pesticides (508 list) on ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

21439

Application Specific

EPA Method 525.2 on ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

21438

Application Specific

EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

20582

Application Specific

Fast EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea

20572

High Temperature

EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT

Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

18785

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18152

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18151

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18149

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18148

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18147

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18146

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18145

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 3u Phenyl Hexyl

Luna 3 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2 mm, Ea

17981

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi 2.5u Hydro Rp

Synergi 2.5 µm Hydro-RP 100 Å, LC Column 100 x 2 mm, Ea

17980

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi 2.5u Polar Rp

Synergi 2.5 µm Polar-RP 100 Å, LC Column 100 x 2 mm, Ea

17979

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini 5u NX

Gemini 5 µm NX-C18 110 Å, LC Column 250 x 4.6 mm, Ea

17959

Normal Phase

EPA Method 8330: Explosive Mix Using Hyperclone 5u CN

HyperClone 5 µm CN (CPS) 120 Å, LC Column 250 x 4.6 mm, Ea

17958

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini C6 Phenyl

Gemini 5 µm C6-Phenyl 110 Å, LC Column 250 x 4.6 mm, Ea

17957

Reversed Phase

EPA Method 8330: Explosive Mix Using Hyperclone ODS C18

HyperClone 5 µm ODS (C18) 120 Å, LC Column 250 x 4.6 mm, Ea

17956

Normal Phase

EPA Method 8330: Explosive mix Using Luna 5u CN

Luna 5 µm CN 100 Å, LC Column 250 x 4.6 mm, Ea

17955

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 5u PFP

Luna 5 µm PFP(2) 100 Å, LC Column 250 x 4.6 mm, Ea

17954

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini 5u C18

Gemini 5 µm C18 110 Å, LC Column 250 x 4.6 mm, Ea

17953

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 5u C18

Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea

17952

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Polar RP

Synergi 4 µm Polar-RP 80 Å, LC Column 250 x 4.6 mm, Ea

17951

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

17913

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

17912

Standard

EPA Method 8270C on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16584

EPA Method 8270C ZB-5MSi

16413

Application Specific

EPA Method 8270C on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16275

EPA 8081: Organochlorine Pesticides on ZB-MR2

16160

Application Specific

EPA 8081: Organochlorine Pesticides on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.53 mm x 0.50 µm, Ea

16159

EPA 8081: Organochlorine Pesticides - Fast on ZB-MR2

16158

Application Specific

EPA 8081: Organochlorine Pesticides - Fast on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.53 mm x 0.50 µm, Ea

16157

Application Specific

EPA 8081: Organochlorine Pesticides on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16156

Application Specific

EPA 8081: Organochlorine Pesticides on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16155

Application Specific

EPA 8081: Organochlorine Pesticides - Fast on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16154

Application Specific

EPA 8081: Organochlorine Pesticides - Fast on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16153

Application Specific

EPA 8081: Organochlorine Pesticides on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

16152

Application Specific

EPA 8081: Organochlorine Pesticides on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16151

Application Specific

EPA 8081: Organochlorine Pesticides - Fast on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

16150

Application Specific

EPA 8081: Organochlorine Pesticides - Fast on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16149

EPA Method 8081 - Organochlorine Pesticides on ZB-1ms

15882

Application Specific

EPA Method 8081 (Organochlorine Pesticides) on ZB-1701P

Zebron ZB-1701P, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15881

Standard

EPA method 8081: Organochlorine Pesticides

Zebron ZB-50, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

15785

Standard

EPA method 8081: Organochlorine Pesticidesl on ZB-1

Zebron ZB-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

15784

Standard

EPA Method 8081: Chlorinated Pesticides

Zebron ZB-50, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15698

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea

15696

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15695

Standard

EPA Method 8270C on ZB-5MS 30x0.25x0.25

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14953

Standard

EPA Method 8270C on Guardian on ZB-5

Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14945

Standard

Nitroaromatics - EPA Method 609: ZB-5 15x0.53x1.5

Zebron ZB-5, GC Cap. Column 15 m x 0.53 mm x 1.50 µm, Ea

14866

Standard

EPA Method 525.2: Organic compounds in Drinking Water on ZB-5 on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14771

Reversed Phase

EPA Method 8330 Explosives mix using Synergi Polar-RP

Synergi 4 µm Polar-RP 80 Å, LC Column 250 x 4.6 mm, Ea

14769

Reversed Phase

EPA Method 8330 Explosives mix using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

14768

Standard

8270 Semi-Volatile Organic Analysis on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14567

Standard

Semivolatiles (BNA) by GC/MS (EPA Method 8270C)

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea

14442

Reversed Phase

EPA Method 8330 - Explosives on Luna C18(2)

Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea

14263

Reversed Phase

Explosives (EPA Draft Method 8330)

Ultracarb 5 µm ODS (20) 90 Å, LC Column 250 x 4.6 mm, Ea

5634

PAH with Surrogate Standards on Envirosep-PP (Flu), EPA Method 610

5300

PAH with Surrogate Standards on Envirosep-PP (UV), EPA Method 610

5299